7. CONFIGURATION PROCESS

If more than 10 sec-
onds elapse between
pressing two keys,
the programming step
must be entered again.
If more than 30 sec-
onds pass, the call is
aborted or the set-up
mode is terminated.
Enter code and data,
for example: *11*012341234#
(cf. table of configuration steps)
2 short beeps?
One long sound. Invalid input. The last
code must be entered again.
Remote configuration using an external
DTMF-enabled telephone
Dial the elevator emergency phone
number
Several elevator emergency intercom
stations (cf. page 39) operated on one
telephone line?
1 beep (all connected elevator emergency
telephones answer)
Press device numbers [1 - 9] to connect
with the corresponding device. If only
one elevator emergency intercom is
connected, please wait shortly until you
hear 3 beeps.
Attention: must be directly configured at
the elevator emergency phone.
3 beeps (requested
intercom stations respond)
To start the configuration mode enter
2 short beeps (waiting for password)
Enter password,
press the following:
*
(0000 factory default password)
Valid password?
2 short beeps
(Start programming mode)
Continue programming?
configurAtion proceSS
On site using the keypad of the 99-1050
elevator emergency telephone
To start programming
quickly press the following:
#
Wrong password
(one long sond)
Press
* #
*
2 short beeps
Connection disconnected or end of
programming
Elevator emergency telephone is
restarted with new settings
Behnke AT2 Manual
41