Hawa Motronic 60/100/140 SMI

2 Product information

Intended use
Drive with integrated controls for automating wood, metal or aluminum sliding shutters with SMI 3.0 BF interface.
Intended place of use
External area with a rural inland climate, no particularly high pollution burden and at least 20 km (12.4 mi) away from the sea.
Technical data
Hawa Motronic 60/100/140 SMI
Power supply
Max. Pre-fuse
Overvoltage category
Protection class
Operational temperature range
Degree of siuling
IP degree of protection
Max. speed
Max. drive force
Operating type
Control current (CW, CCW)
Internal resistance Control circuit
Max. cable capacity of the connecting cables
Operating facilities
Power interruption
Important note concerning connection to an SMI (Standard Motor Interface) interface
It is essential to adhere to the valid SMI specifications (www.standard-motor-interface.com).
Before connecting to an SMI system, a teach-in run must take place, see chapter 6; Commissioning!
Delivery condition position OPEN (0%) = Left outer facade sliding shutter position
Position OPEN (0%) (Left outer facade sliding shutter position):
Byte Parameter 20h (PAR_ADR_W, Domain D0 / D11)= 00 (PAR_BY_W)
for right outer facade sliding shutter position, change to
Position OPEN (0%) (Right outer facade sliding shutter position):
Byte Parameter 20h (PAR_ADR_W, (Domain D0 / D11)= 01 (PAR_BY_W)
More information can be found at: SMI Data protocol SMI 3 Specification / Chapter 4.10
Our manufacturer address= 16 (10h)
After a power interruption, the sliding shutter always moves to the open position (0%) first to "calibrate" itself!
Only then is the required (SMI) command executed.
100 – 240 VAC, 50/60 Hz, 30 W
16 A
II
I
-20° C bis +60° C
1
IP 54
Hawa Motronic 60 SMI
Hawa Motronic 100 SMI
Hawa Motronic 140 SMI
100 N (protected internally against
overload)
S2 - 1 min
max. 1.97 mA @ 264 VAC
> 134 k0hm
30 nF (≙ approx. 400 m (1312' 4 ") with halogen-free cable,
1
approx. 200 m (656' 2 ") with PVC cable)
---- -
32
• "Only" via push button
• With a connection to a bus system, we recommend a "normal" module
(e.g. for actuating a lamp) Do not use shutter modules or the like.
• Direct to an SMI module
For safety reasons, the first run after a power interruption must always take
place at reduced speed, and an end point must first be reached so that fully
functional operation is guaranteed.
EC conformity mark
15
10 cm/s (3 "/s)
---- -
16
3
7 cm/s (2 "/s)
- -
4
31
5 cm/s (1 "/s)
---- -
32
Gold contacts may be required
1
---- -
32
11/20