Automatic defrost

At low room temperatures, frost may build up
on the evaporator during operation. The unit will
automatically start to defrost while the POWER
indicator light keeps blinking.
A. In cool or dry mode: After the compressor
has run for 20 minutes, the coil temperature
sensor will start to check the temperature. When
the coil temperature is below -1°C and lasts over
3 minutes, the compressor will stop working. Then
the fan will run at high speed and POWER indicator
will blink. When the coil temperature goes up to
7°C, the compressor will start to work again for
either cool or dry mode.
B. In heating or dry mode: After the compressor
has run for 20 minutes, the coil temperature sensor
will start to check the temperature. When the coil
temperature is below 40°C and coil environmental
temperature ≤19°C, and both temperatures last
over 3 minutes, the compressor and fan will stop
working. After 1 minute the compressor will start
to work again for auto defrosting. After 5 minutes,
the unit will exit the defrost program. During
defrosting, the POWER indicator light keeps
blinking.
Drainage
Manual drainage
When the water tank at the bottom is full, the
display will show error code " ". The appliance will
buzz 10 seconds then stop working.
1. Turn off the appliance then disconnect from
the power supply.
2. Place a suitable water container below the
lower drain outlet.
3. Remove the outlet plug to let the drained water
flow into the container. Afterwards, re-locate
the plug.
4. Now the appliance can operate again.
GE959_ML_A5_v1_20230104.indb 9
GE959_ML_A5_v1_20230104.indb 9

Continuous drainage

The self-evaporating system uses the collected
water to cool the condenser coils for better
performance, so there is no need to empty the
drainage tank in cooling operation except in drying
operation and high humidity conditions.
For continuous operation or unattended operating
in dry mode, the supplied drain hose should be
connected to the unit.
1. Turn off the appliance and disconnect from the
power supply.
2. Remove the plug of the upper drain outlet and
connect the supplied drain hose, ensuring the
hose is not kinked and clear of obstruction.
3. Place the other end of drain hose over a drain
pipe or a container suitable for collecting
waster water.
Drain hose
Caution:
Do not submerge the end of hose into water,
as this may cause "Air Lock" in the hose.
Due to the negative pressure of condensate
drain pan, you can tilt the drain hose
downward toward the floor. It is appropriate
that the inclination should exceed 20 degrees.
Straighten the hose to avoid any trap inside
the hose.
Cleaning, Care &
Maintenance
Switch off and disconnect from the power
supply before cleaning.
Clean the external surface using a damp cloth.
Always wipe dry after cleaning.
DO NOT allow any moisture to enter the
interior via any air inlet/outlet.
Clean all air inlets/outlets with a small, soft
brush.
EN
9