Cleaning the air filter (every two weeks)
Dust collecting on the filter will restrict the airflow. The restricted airflow will reduce the efficiency of the
system. If blocked, it may cause damage to the unit. Clean the air filter regularly.
1. Turn off the appliance then disconnect from the power supply.
2. Remove the air filter on the back and clean with a vacuum cleaner.
3. If necessary, rinse the air filter under running water for a thorough cleaning.
4. Set aside and allow the filter to air dry completely before reinstalling. NEVER operate the unit
without the air filter in place, or the evaporator may be contaminated.
During cleaning, take caution to avoid touching the evaporator surface. Caution: Risk of
injury to the fingers.
Storage: If not to use for an extended period of time, it is recommend to dry the unit out completely.
Switch off and disconnect from the power supply.
Remove exhaust hose and window kit. And ensure to drain all waste water from the unit.
The internal evaporator has to be dried out as well to avoid mildewing. You can place the unit in a dry
open area for days to dry out. Another way is to turn on the machine, run it with low-wind ventilation
mode, and maintain this state until the drain pipe becomes dry.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
Unit not working
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Decreased air flow
Filter is dirty
Air inlet/outlet is blocked
Room door or window is open
Exhaust hose is detached
Water leakage
Overflow while moving unit
Drain hose is kinked or bent
Excessive Noise
Unit is not positioned level
Loose or vibrating parts
Unit stops suddenly,
Water tank at the bottom is full
Error code " " on
display
E0
Communication fault between
main PCB and display PCB
E1
Ambient temperature sensor
Error code
failure
E2
Coil temperature sensor failure
10
GE959_ML_A5_v1_20230104.indb 10
GE959_ML_A5_v1_20230104.indb 10
Probable Cause
Solution
Check the unit is plugged in correctly and
switched on
Replace plug or lead
Replace the fuse
Check mains power supply
Clean the filter
Remove all blockage
Close door or window
Install the exhaust hose securely
Empty the water tank before transport
Straighten the hose to avoid any trap existing
Place on flat and firm ground
Secure the parts
Refer to the section "Manual drainage" on how
to Empty the water tank
Check the wire harness of the display PCB for
damage
Check the connection. If necessary, clean or
replace with a new one
Check the connection. If necessary, clean or
replace with a new one
2023/1/4 17:37:20
2023/1/4 17:37:20