Install Solar Crystalline series modules in the following conditions:
.Operating temperature:
. Storage temperature:
. Humidity:
. Altitude:
. Mechanical Load Pressure:
*Mechanical load bearing specifications of the module is based on our Solar
mounting methods. A professional system installer must be responsible for the
mechanical load calculations based on the specific system design.
*The modules have been evaluated by TUV according to IEC61215 for a maximum
positive design loading of below 2400Pa, and negative design loading 1600Pa,with 1.5
times safety factor.
2) Limited conditions
Installation environment with following conditions should be avoided.
·The installation area with extreme sand and dust damage.
·The installation position with extreme air pollution, chemical vapors, acid rain, and/or
soot, etc.
·The installation place with extreme hail and snow damage.
·The installation location with extreme salt damage.
Checklists:
·All fastenings are tight, secure and free of corrosion.
·All cable connections are secure, tight, clean and free of corrosion.
·Cables are not damaged in any way.
·Verification of the grounding resistivity of metals.

Maintenance and Cleaning

Do not change the PV components (diode, junction box, plug connectors) that can be
serviced by
module a sufficient tilt (at least 15°) to keep one self-clean effect in normal conditions
(rainfall will have a self-cleaning effect). When heavy soiling happened on the module
(which will result in output reductions), we use a gentle cleaning implement (such
as a sponge) and water (from a hose) without clean agents to rinse the modules. Dried
dirt must never be scraped or rubbed, scraping and rubbing module surface will cause
micro-scratching. Periodic inspection must be done for the system.
Module Specifications
Please refer to the latest Module datasheet for more details.
authorized distributor or dealer without voiding the warranty. Given the
-40℃ to +85℃
-20℃ to +50℃
below 85RH%
≤2000m
2400Pa (245 Kg/m2)