Fig. 3: Drilling dimensions [mm]
u Using a suitable tool, break out the required
cable entry point at the predetermined location,
if necessary.
u Insert the membrane gland (included in delivery
contents) into the respective cable entry point.
u Insert the supply line and the control / data line
into the product through the cable entry point.
In order to prevent moisture entering the
enclosure, MENNEKES recommends using
the cable entry point on the bottom side or
the reverse side if mounting outdoors
without a protective cover.
Placement
Ø cable
entry point
Top side
Each 3 x
and bottom
Ø20 mm ±
side
0.7 mm
Each 1 x
Ø25 mm ±
0.7 mm
Membrane gland
(delivery contents)
Membrane gland
with strain relief
(CLIXX© 20 BK) for
cable diameters from
6 to 13 mm
Membrane gland
with strain relief
(CLIXX© 25 BK) for
cable diameters from
9 to 17 mm
Placement
Ø cable
entry point
Reverse
3 x
side
Ø32.5 mm
Approx. 65 cm of cable is required for the
supply line inside the product.
u Fasten the product to the wall using dowels and
screws. Select the tightening torque according
to the building material of the wall.
u Check the product for firm and secure attach-
ment.
Sealing plugs
1
Fig. 4: Sealing plugs
u Cover fastening screws with the sealing plugs
(1) (included in the scope of delivery).
ATTENTION
Material damage due to missing sealing plugs
If the fastening screws are not covered, or are not
adequately covered with the sealing plugs
provided, the specified IP rating is no longer guar-
anteed. This can lead to consequential damage of
electronic components.
u Cover fastening screws with the sealing plugs.
Membrane gland
(delivery contents)
Membrane gland
without strain relief