Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Maintenance; Cleaning The Device; Troubleshooting - Waeco AirCon Service TP-9360 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
I
NOTE
If the sensor probe is held over a
refrigerant leak, the leak signal will
gradually fade.
3. If a refrigerant leak is detected, pull the
sensor probe away for a few seconds and
bring it back to further specify the leakage
location.

Cleaning and maintenance

Cleaning the device

A
NOTICE! Damage hazard
• Do not bring the housing of the
device into contact with solvents
such as gasoline.
• Ensure that no water or cleaning
agent enters the housing of the
device.
➤Occasionally wipe the housing of the device
with household cleaning agent or isopropyl
alcohol.
➤Wipe the tip of the sensor probe with a
clean, dry cloth.
Replacing the sensor probe filter
The sensor probe filter needs to be changed
when it becomes plugged with water or oil.
1. Pull the sensor probe filter out of the tip of
the sensor probe.
Use a paper clip or similar object as a tool.
2. Push the new sensor probe filter into the
tip of the sensor probe.
EN

Troubleshooting

Fault
The device
does not
work
The device
responds
slowly to
leaks
4445103960
Possible
Solution
cause
➤ Replace the
Sensor
sensor (chap-
defective
ter "Installing
or replacing
the sensor" on
page 6)
➤ Set sensitivity
Sensitivity
to high (chap-
set to low
ter "Changing
the sensitivity
setting" on
page 6)
➤ Replace the
Sensor probe
sensor probe
filter is dirty
filter (chapter
or wet
"Replacing the
sensor probe
filter" on
page 7)
➤ Turn on the
Failure in the
product and
pumping
listen to a high
system
pitched motor
sound.
If the motor
cannot be
heard contact
an authorized
service agent
➤ Ensure the
Sensor cover
sensor cover is
does not seal
installed prop-
properly
erly (chapter
"Installing or
replacing the
sensor" on
page 6)
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis