Earthing
Poor earthing is the most likely cause of poor performance of the energiser; please
follow these simple rules;
1. Wet/Clay ground makes good earthing – Dry/sandy soil is a poor earth
2. Use good quality earth stakes that are galvanized – A piece of iron will not
work for very long
3. DO NOT connect the earth to a building/water pipes etc.
How to Test the Earthing
1. Short the fence
using 2 metal
bars
2. Using your fence
tester push the
probe into the
ground
22
Switch on energizer. Charging will start. Once
charging has started energiser can be switched
off. To charge a flat battery it will take 24 hours.
The mains adapter will run the energiser if there
is no battery. The solar/adapter light will be on
when charging.
To get good earthing it may be necessary to have more than
1 earth stake. Extra earth stakes should be 1m from each
other and connected together with high quality double
insulated high voltage cable.