deTAiLed peRFORMAnce dATA FOR use On ROund pipes
Values shown for load capacity of the TML 400 R are based on material S235 JR for the maximum, vertical
tractive force with 0° deviation from the load axis and a correct position of the pipe inside the groove of
the magnetic contact area. The safety factor corresponds to at least 3:1 in all cases.
Table 3: Round pipes
mm
inches
Rust, paint or any other surface coating may cause an air gap that will reduce the load-bearing capacity
according to the following table.
Tabelle 4: Tragfähigkeit bei Luftspalt
Air gap in mm
Air gap in inch
Remaining
load capacity in %
50
75
>10
150
8
145
5
130
4
95
3
75
2"
3"
>3/8
330
5/16
319
0.20
286
0.16
209
1/8
165
0
0.2
0
0.0078
100
89
Load capacity in kg
100
200
200
175
200
175
175
150
130
112
100
90
Load capacity in lbs
4"
8"
440
385
440
385
385
330
286
246
220
198
0.4
0.6
0.0157
0.0236
75
65
Quick and abrupt rotations of
!
the magnet can cause round
object to disengage from
the magnet's groove. This
will reduce the load-bearing
capacity immediately.
!
400
200
-
200
-
175
-
130
-
100
16"
440
-
440
-
385
-
286
-
220
1.0
1.5
0.0393
0.0590
45
30
never lift round pipes laterally
or exceed the load-bearing
capacity given in table 3 & 4.