▶ Secure one carabiner of the tool tether to the retaining strap and secure the second carabiner to a
load-bearing structure. Check that both carabiners hold securely.
Comply with the operating instructions of the Hilti retaining strap and those of the Hilti tool tether.
5.5
Changing the nosepiece
CAUTION
Risk of injury A blind rivet can injure you.
▶ Make sure there is no blind rivet in the fastening tool.
1. Press and hold down the trigger.
2. Use a ring wrench of the correct size (12 mm) to slacken the nosepiece and unscrew it.
3. Screw the new nosepiece into position.
4. Use a ring wrench of the correct size to tighten the nosepiece.
6
Operation
Observe the safety instructions and warnings in this documentation and on the product.
6.1

Setting a blind rivet

1. Install the correct nosepiece for the rivet diameter you are going to use.
2. Insert the blind rivet into the nosepiece.
3. Hold the product in position on the workpiece.
Only predrilled workpieces can be riveted.
4. Press the trigger to set the blind rivet.
5. Tilt the product to the rear so that the sheared rivet mandrel can drop into the mandrel container.
6.2

Emptying the mandrel container

1. Turn the mandrel container counter-clockwise to remove.
2. Empty the mandrel container.
3. Screw the mandrel container back on to the product.
7

Care and maintenance

WARNING
Risk of injury with battery inserted !
▶ Always remove the battery before carrying out care and maintenance tasks!
Care of the product
Carefully remove stubborn dirt.
Carefully clean the air vents, if present, with a dry, soft brush.
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Use a dry, clean cloth to clean the contacts of the product.
Care of the Li­ion batteries
Never use a battery with clogged air vents. Clean the air vents carefully using a dry, soft brush.
Avoid unnecessary exposure of the battery to dust and dirt. Never expose the battery to high levels of
moisture (e.g. by being dipped in water or left in the rain).
If a battery has been soaked by moisture, treat it as a damaged battery. Isolate it in a non-flammable
container and consult Hilti Service.