9. Troubleshooting
Description of Error
Icon stays on
Icon stays on
Icon flashing

10. Frequently Asked Questions

1.
What type of battery chemistry is used in this product?
This product uses high quality lithium iron phosphate.
2.
How do I clean the battery?
The battery can be wiped with a dry, soft, and clean cloth or tissue.
3.
Are lithium batteries safe?
The EcoFlow LFP Battery is protected by high-performance BMS and have undergone rigorous testings to ensure
safety in use.
Can the 5kWh LFP Battery and 2kWh LFP Battery be used in parallel?
4.
This is not recommended — when using two models in parallel, the consistency of the batteries cannot be
guaranteed, which can lead to shortened life span of the batteries or even a safety hazard.
Can I charge the battery at low temperature?
5.
Yes, when the battery is being charged at low temperature -20°C ≤ T ≤ 0°C (-4°F ≤ T ≤ 32°F), the charge heating
function is switched on prior to heat the battery before it is charged normally.
Can the battery be used with third-party power systems?
6.
Yes, the user will need to perform extra wiring for this.
How do I store the battery?
7.
When storing the battery, first switch it off and then store it in a dry, ventilated place at room temperature and
stay away from water sources.
Can the battery be heated when charging with MPPT at ambient temperature below 0°C (32°F)?
8.
Yes. Depending on the intensity of solar radiation and the power of the solar panel used by the user. It is
recommended to connect to at least 400W of solar panel(s).
Error Type
Low Temperature Indicator
High Temperature Indicator
Over-Discharge Protection
Overcharge Protection
Overload Protection
Short-Circuit Protection
Overcurrent Protection
Recovery Methods
Charging: Automatic recovery after battery
temperature above 5°C (41°F)
Discharging: Automatic recovery after core
temperature above -17°C (1.4°F)
Charging: Automatic recovery after cooling to below
42°C (107°F)
Discharging: Automatic recovery after cooling to
below 52°C (125°F)
Battery charging, automatic recovery
when SOC > 0%
Charging stops and recovers automatically
after partial consumption of battery power
Remove the overpowered device and
restart the machine to recover it
Professional inspection recommended to eliminate
the cause of the short circuit
Remove the overcurrent device and
restart the machine to recover it