6.4 - INSTRUCTIONS FOR FIRST START-UP
GARDA EVO CENTR/DT C6500/W
DESCRIPTION AND CHARACTERISTICS
Garda Evo is a combined group consisting of a gearbox that allows the activation of two outputs (blade pumps, blowers,
centrifugal pumps, high pressure pumps and PTO) alternate or simultaneously, from a single PTO. This initial start
information applies to Garda Evo centr.-DT-W, consisting of gearbox, PTO drive and centrifuge pump (output A) and
rotary blade vacuum pumps (MEC II / BALLAST / KTS etc.) (output B).
Parameters
RPM PTO *
ROTARY BLADES VACUUM PUMP PRESSURE
ROTARY BLADES VACUUM PUMP
HYDRAULIC RAM
*The input speed affects the speed in output A/B.
for use and maintenance of the combined groups for the GARDA EVO series
[rpm]
[bar]
[bar]
[rpm]
Lubrication oil rotary blades vacuum pumps
ISO VG 100
Lubricating oil Garda Evo
ISO VG 460
3.8÷4.2 litres
Oil change 300 hours /12 months
Work parameters:
850 ÷ 900
0.5 ÷ 1
-0.5 ÷ -0.8
*
Instruction manual
Max Parameters
1000
1.5
-0.95