After configuring the parameters marked with
matically. It will resume work according to the new parameter value.
Due to the length limit of the LCD displayed data. When the baud rate is set to
115200, the value displayed on the LCD is 1152.
For the parameters marked with
in chapter 7 Protections. Otherwise, the parameter settings will not succeed.
Protections
1) Input Voltage Protection
• The following rules must be followed when modifying the battery's input
voltage parameters:
• Detailed status is shown as the following when the input voltage protection
occurs.
Input Voltage Protection
Over voltage protection
Over voltage recovery protection
Low voltage protection
Low voltage recovery protection
Although the inverter is supplied with the input over-voltage protection, the
surge voltage cannot higher than 20V for the 12V system, not higher than 40V
for the 24V system, and not higher than 80V for the 48V system. Otherwise, the
inverter may be damaged.
CAUTION
, the inverter will restart auto-
, please set them by the input voltage rules
The output is switched OFF immediately.
The green indicator fast flashes. Buzzer beeps.
The green indicator is ON solid.
The output voltage is normal.
The output is switched OFF immediately.
The green indicator Slowly flashes.Buzzer beeps.
The green indicator is ON solid.
The output voltage is normal.