Wire, terminals, and circuit breaker selection for battery
Model
ECO3000W(HN)
120Vac/230Vac
According to the recommended battery wire size, 2 battery wires, connected
in parallel are necessary for the 230Vac outpur version and 4 battery wires
connected in parallel are necessary for the 120Vac output version.
The above wire size and circuit breaker size are for reference only;
please choose a suitable wire and circuit breaker according to the
actual situation.
CAUTION
Wire and circuit breaker selection for AC output
Model
ECO3000W(HN)
(120Vac)
ECO3000W(HN)
(230Vac)
•
please choose a suitable wire and circuit breaker according to the
actual situation.
•
CAUTION
the inverter and the battery, larger wires should be used to reduce
voltage drop and improve system performance.
5.3Mounting
Installation procedures:
Step 1: Read this manual carefully.
Step 2: Determine the installation location and heat-dissipation space
The inverter should be installed in a place with sufficient airflow through the dissi-
pation pad of the inverter. And a minimum clearance of 150mm from the upper
and lower edges of the inverter is recommended to ensure natural thermal
convection.
Battery wire size
25mm2/3AWG
Wire size
6mm2/10AWG
4mm2/11AWG
The above wire size and circuit breaker size are for reference only;
The wire size is only for reference. If there is a long distance between
Ring terminal
RNB60-6
-11-
Circuit breaker
DC-100A(2P in parallel)
Circuit breaker
AC/2P—50A
AC/2P—25A