• Loose power connectors and corroded wires may result in high heat, melt wire
insulation, burn surrounding materials, or cause a fire. Ensure tight connections
and secure cables with cable clamps to prevent them from swaying in moving
applications.
• The DC input voltage must strictly follow the parameter table. Too high or too low
DC input voltage affects the normal operation and may damage the inverter. DC
input 12V: Surge voltage < 20V. DC input 24V: Surge voltage < 40V. DC input 48V:
Surge voltage < 80V.
• Select the system cables according to 3.5A/mm2 or less current density.
• Avoid direct sunlight and rain infiltration when installing it outdoor.
• After turning off the power switch, do not open or touch the internal component
immediately. Performing related operations after 10 minutes is recommended.
• Do not install the inverter in a harsh environment such as humid, salt spray,
corrosion, greasy, flammable, explosive, or dust accumulation.
• The AC output is of high voltage, do not touch the wiring connection to avoid
electric shock.
• To prevent injury, do not touch the fan while it is working.

5.2Wire Size and Circuit Breaker

The wiring and installation methods conform to the national and local electrical
code requirements.