When supplying power for different loads, it is recommended to first
turn on the load with a large impulse current. And then turn on the load
with a smaller impulse current after the load output is stable.
CAUTION
(4)If the FAULT indicator flashes red and the buzzer alarms after powering the
inverter, please immediately turn off the load and the inverter. Clear the faults
according to chapter 8 Troubleshooting. After clearing the faults, please operate
the inverter again by following the above steps.

Parameters Setting

ECO parameters such as power saving mode, baud rate, output voltage class, and
output frequency class can be set on the remote meter, phone APP, or PC
software. The following chapters take parameters setting on the remote meter as
an example (for connection of the remote meter, please refer to chapter 5.3
Mounting).

6.1Power Saving Mode

Users can enable the power saving mode and set the PSI/PSO value by the
remote meter (The minimum power step is 1VA).
When the actual load power is lower than the PSI (the power to enter the power
saving mode), the system will automatically switch to the power saving mode. And
then, the device output is turned on for 1s and turned off for 5s.
When the actual load power exceeds the PSO (the power to exit the power saving
mode), the inverter will automatically exit the power saving mode and resume
work.