Herunterladen Inhalt Inhalt Diese Seite drucken

Problems, Alarms, Useful Advices; Useful Info; What Happens If - klover DEA ECO 6 Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 90
CS.SE.IST-1 / Rev 1.0

PROBLEMS, ALARMS, USEFUL ADVICES

Useful info...

Listed below is some important information regarding the appliance:
-
It is normal for the appliance to emit a smell of paint during its first few days of operation. We recommend ventilating the installation room during
the initial start-up. For the first few days of operation we also recommend that you run the appliance at high power.
-
The boiler unit is treated with anti-oxidant paint in order to protect it against oxidation in the event of long periods of inactivity. After initial start-up,
this paint no longer preserves its original features and any wear of the paint inside the combustion chamber should not be regarded as a
manufacturing fault.
-
Do not clean with water inside the combustion chamber; any oxidation of the combustion chamber after a long period of inactivity is not to be
considered as a manufacturing fault.
-
Any perceived noise during operation may be caused by the expansion settling of the plates that make up the boiler unit. These noises are
accentuated especially during ignition and switching off phases of the appliance and are not to be considered a manufacturing fault.
-
If ignition fails, empty the pellets out of the brazier; only then should you reignite the appliance.
-
Any perceived smoke smell (especially during ignition) is not to be considered a manufacturing fault.
-
The appliance works exclusively with wooden pellets; do not burn different fuels.
-
The noise level of the appliance is emphasised if the pellet container is empty. Therefore we recommend that you always keep the pellet level to
at least half tank.
-
If there is soot and fine particulate in the room where the appliance is installed, check the seal on the flue gas pipes and the filter of the ash vacuum
device used for cleaning.

What happens if...

...the pellets do not ignite
If the ignition fails, the display will show the alarm message "IGNITION FAILED".
Cancel the alarm and reset the appliance to standard condition by pressing key 4 (On/Off) for a few seconds.
If ignition fails, empty the pellets out of the brazier; only then should you reignite the appliance.
...the fire door is open or not properly closed
If the door is left open or not properly closed, the pellet loading will not start, therefore the appliance will not switch itself on. If the door is opened
during normal operation, the appliance switches to "THERMAL SAFETY" alarm.
...the flue pipe is dirty, blocked or not correctly installed
If the flue is dirty, blocked or incorrectly manufactured, pellet loading will not start, thus the appliance will not switch itself on. If the flue is obstructed
during normal operation, the appliance switches to "DEPRESS.-FAILURE" alarm.
...the pellet tank goes in over-temperature
If the pellet container is overheated (>85°C), the pellets will not be loaded because the manual reset thermostat cuts in. If this happens during normal
operation, the appliance switches to "THERMAL SAFETY" alarm. It is therefore necessary to reset the "manual reset thermostat" (see "Components
of the appliance") before switching the appliance on again. To reset, it is necessary to remove the black cap and press the button below.
...lack of power (blackout)
If a power blackout occurs for a shorter time than Pr48, when power is restored, the appliance will immediately re-start in the working mode (recovering
the set working power).
16