LED charging indicators
Fast flash = 0.2S ON and 0.2S OFF
Blinking = 0.2S ON and 1.8S OFF
Flashing = 0.5S ON and 0.5S OFF
LED
Double blinking in sequence
Blinking in sequence
One bar flashing
Two bars flashing
Three bars flashing
Four bars flashing
Lead acid charging and maintaining process
Voltage
(VOLTS)
Current
(AMPS)
1) Qualification – Checks battery condition to determine whether the rejuvenation
stage or charge cycle is required.
2) Rejuvenation – Automatic stage for batteries in poor condition. Breaks down low
levels of sulphation using new patented technology. Note: this mode will not recover
batteries with severe levels of sulphation as this is a permanent and irreversible
condition.
3) Soft start – Increases your battery life by gently starting to charge the battery until
the battery reaches a set Voltage.
4) Bulk charge – Reduces charging time by delivering maximum charge until the
battery reaches a set Voltage.
5) Absorption – Uses constant Voltage and ensures the battery receives a full charge
without overcharging the battery.
6) Equalisation – Restores full capacity to batteries by removing acid stratification.
7) Analysis – Checks the battery condition to ensure it is fully charged.
8) Float – Maintains the battery at 100% charge.
9) Maintenance – Special pulse charge for long-term maintenance to ensure the
battery is in optimal condition.
Status
All bars off
On
Descriptions
Battery condition check
Rejuvenation phase
Soft start phase
Bulk charge (less than 13V)
phase
Bulk charge (above 13V)
phase
Absorption or repair phase
Power supply mode active
Float phase or maintenance
phase. Battery is fully
charged