Short circuit and reverse polarity protection
The charger is designed to protect against short circuits or reverse polarity connection.
If detected it will automatically turn off to prevent damage.
Never overcharge your battery
The charger will protect against and prevent overcharging.
Heavy duty cables and dual clamp
Supplied with robust cables for longevity. Innovative design featuring clamp and eyelets
means only one cable set is required.
Temperature and safety protection
Internal overheat, timer, reverse polarity, and short circuit protection.
Eco mode
This charger has a built in ultra-low power consumption circuit. If mains power is connected
and the battery is disconnected, after 30 seconds the charger will automatically go into eco
mode. During this mode, the power drawn is less than 0.36W which totals 0.01kWh per day.
If mains power is connected and the battery is connected, once the battery is fully charged
and during the maintenance stage, the total power consumption is around 0.03kWh per day.
The power LED light will flash red to indicate eco mode is on.