7. OPERATION:
TIP:
When starting the engine, with the ESC "ON", and there is no load on the generator:
• in ambient temperature below 0°C(32°F), the engine will run at the rated r/min
(5000r/min) for 5 minutes to warm up the engine.
• In ambient temperature below 5°C(41°F), the engine will run at the rated r/min
(5000r/min) for 3 minutes to warm up the engine.
The ESC unit operates normally after the above time period, while the ESC is "ON".
4. Pull slowly on the recoil starter
until it is engaged, then pull it
briskly.
TIP:
Grasp the carrying handle rmly to
prevent the generator from falling
over when pulling the recoil starter.
5. After the engine starts, warm up
the engine
until the engine does not stop
when the choke knob is returned to
"ON" position ④.