Herunterladen Inhalt Inhalt Diese Seite drucken

MALTEC DH-12000 Bedienungsanleitung Seite 20

Luftentfeuchter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

 Do not use an extension cord or an adapter plug.
 Do not put objects on the unit.
 Do not climb or sit on the unit.
 Do not insert fingers or other objects into the air outlet.
 Do not touch the air inlet or the aluminum fins of the unit.
 Do not operate the unit if it is dropped, damaged or showing signs of product
malfunction.
 Do not clean the appliance with any chemicals.
 Ensure the unit is far away from fire, inflammable, or explosive objects.
 The unit shall be installed in accordance with national wiring regulations.
 Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture.
 The appliance shall be stored in a room without continuously operation sources (for
example: open flames, an operating gas appliance or an operating electric heater).
 The appliance shall be stored so as to prevent mechanical damage from occurring.
 Do not piece or burn, even after use.
 Be aware that refrigerants may not contain an odor.
 Pipe-work shall be protected from physical damage and shall not be installed in an
unventilated space, if that space is smaller than 4m².
 Compliance with national gas regulations shall be observed.
 Keep any required ventilation openings clear of obstruction.
 The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment authority,
which authorizes their competence to handle refrigerants safely in accordance with an
industry, recognized assessment specification.
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled personnel
shall be carried out under the supervision of the person competent in the use of flammable
refrigerants.
If you don't understand something or need help, please contact the dealer services
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing a
dehumidifier with R290.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating
20/48