Error code
Description
Basic parameter error in flash or RAM - Meter must be replaced
C - 1
E 1
Temperature range outside [ -19.9 ° C...199.9 ° C] e.g. sensor short-circuit,
sensor break
E 3* *
Forward and return sensor reversed
E 4
Hardware error US measurement, e.g. transducer or control defective or short
circuit
E 5
Communication not possible (too frequent read-out)
Flow direction of flow meter incorrect
E - 6* *
E 7
No plausible ultrasound receiver signal, e.g. air in the measuring path
E 8
No primary power supply (only with power supply unit); supply via backup
battery
E 9
Battery nearly discharged, design lifetime reached
E A*
Leak: Pipe break detection
E b*
Leak: Energy meter leak detection
E C*
Leak: Leak pulse input 1
E d*
Leak: Leak pulse input 2
* optional * * application dependent
11.

Disposal

The transposed European Directives on waste batteries and waste electri-
cal and electronic equipment supervise the actions necessary to limit the
negative impact of the product end of life.
This product is subject to special collection and disposal. I t should be
deposited at an appropriate facility to enable recovery and recycling.
For further details about recycling this product, please contact your Diehl
Metering agency.
12.

Declaration of Conformity for devices according to MI D

See from page 97 onwards.
Further information as well as the actual declaration of conformity are
available at:
https:/ / www.diehl.com/ metering/ en/ support-center/ download-center/