Install the radiator in such a way that the minimum distance between
the floor and the thermostat is 250mm and make sure that there are no
obstacles within a minimum distance of 100mm from the appliance.
6.
Wall mounting
The electric radiaotrsmust be mounted on the wall following the
instructions provided in the packaging of fastening supports.
When the radiator is in the proper position, the resistor is located at the
bottom right.
The radiator must absolutely never be installed with the resistor turned
upwards or in any direction other than pointing downwards, as the
heating element in the resistor itself would be irreversibly damaged
during operation.
Never position the radiator in front of the power socket.
Make sure that the resistor never operates unless it is fully submerged.
7.
Connecting up
All models of Cordivari electric radiator are fitted with a power cable
complete with a pre-mounted Shuko plug. Before connecting up, make
sure that the rated voltage of the appliance (230V) corresponds with
the mains voltage, and also check to ensure that the wall socket is
properly earthed in compliance with current regulations and that it is
capable of delivering the rated current required to operate the chosen
model at full power.
8. Cautions
When operating normally the radiaotr has very hot surface.
It is normal for the bottom pipes not to heat up.
Only warm towel that has been washed in water.
The resistors on electric radiators must never operate without filling
fluid, and for this reason the connections on the radiator itself must
never be opened.
In the event of accidental overheating and/or improper use, the
resisitor circuit may cut out. In this event the resistor can no longer be
used, and must be replaced.
9. Replacing of electrical immersion
Should it be necessary to replace the resistor, this must be done
exclusively by the manufacturer, by a person with suitable
qualifications, so as to avoid any risks.
10. Istruzioni termostato
1910000000048 R_077 Rev. 01/2018
a. Power On / Stand-by mode
Press the key [On/Stand-by] to turn on the device or to enter the "Stand-
by" mode. When activated, the bottom part of the display shows the
current time, while the configured operative mode and the temperature
are shown in the upper part. When in "Stand-by" mode current time, day
of the week and the message: " Stb" are displayed.
NOTE: When the device goes into "Stand-by" mode it beeps twice for
0.5s.
When the device is activated it beeps once for 1s.
b."COMFORT" and "NIGHT" MODES
Two different levels of temperature can be set:
- COMFORT TEMPERATURE is the temperature setting for 'Chrono',
'Fil-Pilote' and 'Comfort'modes;
- NIGHT TEMPERATURE is the temperature setting for the 'Night'
and 'Chrono' mode.
The desired temperature can be set pressing the [+] e [ - ] buttons. The
range of configurable temperature is 7°C - 32°C.
IMPORTANT!
The temperature of "Night" mode must be below to the "Comfort" mode
temperature. For this reason the "Night" mode temperature can be set to