Herunterladen Diese Seite drucken

Helo WE-53 Produkthandbuch Seite 8

Schützgehäuse
Vorschau ausblenden Andere Handbücher für WE-53:

Werbung

Additional instructions for connecting the contactor case WE 53 to the sauna heater
and IR panels.
ATTENTION! The Helo Elite control panel must be used when the sauna heater and the IR
panels are being used together.
When infrared heaters are also installed in the sauna room, the IR function must be activated via the settings.
When the IR function is activated, the setting scale is shown in the settings.
The IR heaters are time-controlled. However, the IR heaters will not work if the temperature in the sauna room
is too high or if the required temperature is set above 60°C.
When the IR function is active, the setting level is shown on the display.
When a new sauna session starts, and the IR function has been activated, the heating IR panels are continuously
heated for 20 minutes, after which the IR panels switch to their scheduled operation, depending on the selected
set point (see table).
When the sauna temperature is set to 40°C, the sauna heater will not heat the sauna room at all; rather only the
IR heaters are active. The time the IR heaters remain switched on depends on the selected setting level (see
table). If the temperature is set between 41°C and 60°C and the temperature in the sauna room has not yet
reached the required temperature, the sauna heater will warm up simultaneously with the IR heaters.
The IR heaters are never active in standby mode.
DIP switch positions for the
sauna heater and IR panel.
Activating IR panels.
Select IR from the
menu.
Select Enable to
activate.
Select the
temperature and
program for the IR
panels.
ON
OFF
1
2
3
4
5
6
IR
Time switched
on
0
0
1
1 min 52 sec
2
2 min 09 sec
3
2 min 25 sec
4
2 min 41 sec
5
2 min 57 sec
6
3 min 14 sec
7
3 min 29 sec
8
3 min 45 sec
9
4 min 01 sec
10
Continuous operation up to +60°C
The IR panel scale table: operating
times that can be set from the Helo
Elite control panel.
Time switched off
4 min 20 sec
2 min 28 sec
2 min 11 sec
1 min 55 sec
1 min 39 sec
1 min 23 sec
1 min 06 sec
0 min 51 sec
0 min 35 sec
0 min 19 sec

Werbung

loading

Diese Anleitung auch für:

2005-53