Motor Control System MT-4
6 Commissioning
6.5 Wiring diagram for light barrier HC in the door opening
10 11 12 13 14 15 16 17
Light barrier 1
Transmitter black
Transmitter brown
Receiver brown
Receiver black
Transmitter blue
Receiver blue
7 Operation
The device may only be used in accordance with its proper use (see section 1.8
"Proper use"). The special regulations and safety information for the device apply.
The device is operated in the following operating modes:
» Automatic mode
7.1 Safety information
18 19 20 21 22 23 24 25 26
LS 1
LS 2
Clamp designation
18
18
18
19
20
20
Observe the safety information!
» Observe the safety information in section 2 "General safety
information", in particular in section 2.3 "Safety information
for operation".
Original operating instructions
SKS OSE
Light barrier 2
Transmitter black
Transmitter brown
Receiver brown
Receiver black
Transmitter blue
Receiver blue
DANGER
Clamp designation
21
21
21
22
23
23
02.2022 | 33