4. ASSEMBLE
1) The position of Mounting
First ensure that there is enough space to install the inverter, while the installation location must meet
the following requirements:
① Drying: Do not use water or other liquids dripping on the inverter
② Cool: a working environment temperature of the product is 0-40℃, preferably a temperature of 10-25
℃, at a temperature as low as possible within this range
③ Ventilation: There should be a certain distance between inverter and other objects, to avoid blocking the
products vents.
④ Clean: Do install the products in the dusty, wood chips or other particles , If cooling fan is turned on, the
particles involved in the inside of the product, thus affecting the normal work.
⑤ While inverters and batteries connected, will produce arcs or sparks, so there should not be around
flammable objects such as gasoline, alcohol, etc.
3
LCD Disaplay
USB
POWER
Inverter power switch
Remote controller
LCD Disaplay
USB
POWER
Inverter power switch
Remote controller
Fault indicator
Power indicator
Switch
2) Assemble the inverter
For this big power inverter, because of the heavier weight, preferably mounted on a solid platform, such
as floor, table or mounting bracket fine. In order to avoid falling off, platform for supporting the product
should can bear the weight of sufficient capacity, and it is good with four screws to secure the product.
3) Installation of remote control box
① Fixed on the plane with an opening, then fix two screws directly on the position of two installation holes
of the remote control box.
② The remote control box can also be installed on the base of 86X86mm electrical socket.
③ Connect the connection between the remote control box and the inverter.
Note: This product can also be used as a common inverter without connecting the remote control box.
5. BATTERY
1) Current and voltage of battery
The battery is used to supply the DC input voltage required by the product, and its rated voltage must be
in line with the rated input voltage of the inverter, beyond the input voltage range of the inverter, and the
cross connection will cause the product to be under voltage or under voltage protection.
At the same time, the battery must provide enough current for inverter, a small capacity battery is not
able to drive high power appliances, in this case, usually due to excessive current and battery discharge
the battery terminal voltage low, under voltage protection products appear.
The simple formula for the battery current is the load power / the battery voltage. As the inverter itself will
be part of the loss, so the actual current will be greater than this value of about 10%. For example: the
battery voltage is 12VDC, the load power is 1000W, then the actual current size of the battery is about
1000W÷12V×110%=91.6A
2) Battery working time
The using time of battery depends on battery capacity (AH) and the power of the connected load (W),
the calculating method is: Time (hours) =battery capacity (AH) x battery output voltage (V) x efficiency
rate ÷ electrical power of using (W) such as the 12V DC input inverter uses the 12V battery, if the battery
capacity is 2000AH and at this time the inverter is driving 1000W power load, the efficiency rate is 90%
when the battery is full, according to the formula above, the battery use time =2000(AH) / (1000 /
12x110%) = 21.8 (Hour). This means the battery can be used for 21.8 hours.
Note: The above formula is the calculation result of the battery discharging rate in 20 hours, that is, when
the discharging current of 2000 Ah battery does not exceed 100A, the discharging time will be shortened
when the discharging current exceeds this value. This part can refer to the battery manufacturer's
specifications, and whether the battery is fully charged will also affect this result.
6. CONNECTION
1) Grounding
The power inverter has a terminal on the back panel marked "Grounding" or "
the chassis of the power inverter to the ground. The ground terminal has already connected to the
ground wire of AC output receptacle through the internal connecting wire. The ground terminal must be
connected to the ground wire, which will vary depending on where the power inverter is installed. In a
vehicle, connect the ground terminal to the chassis of the vehicle. On the ship, connect the ground