Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Sygonix 2483200 Bedienungsanleitung

Batteriebetriebener rauchmelder
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Click on the following link to read the full text of the EU declaration of conformity:
downloads
Enter the product item number in the search box. You can then download the EU declaration of conform-
ity in the available languages.
14 Disposal
14.1 Product
This symbol must appear on any electrical and electronic equipment placed on the EU mar-
ket. This symbol indicates that this device should not be disposed of as unsorted municipal
waste at the end of its service life.
Owners of WEEE shall dispose of it separately from unsorted municipal waste. Spent batter-
ies and accumulators, which are not enclosed by the WEEE, as well as lamps that can be re-
moved from the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back of waste.
Conrad provides the following return options free of charge (more details on our website):
in our Conrad offices
at the Conrad collection points
at the collection points of public waste management authorities or the collection points set up by man-
ufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in countries
outside of Germany.
14.2 (Rechargeable) batteries
Remove batteries/rechargeable batteries, if any, and dispose of them separately from the product. Ac-
cording to the Battery Directive, end users are legally obliged to return all spent batteries/rechargeable
batteries; they must not be disposed of in the normal household waste.
Batteries/rechargeable batteries containing hazardous substances are labelled with this sym-
bol to indicate that disposal in household waste is forbidden. The abbreviations for heavy
metals in batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable)
batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or
wherever (rechargeable) batteries are sold. You thus fulfil your statutory obligations and contribute to en-
vironmental protection.
Batteries/rechargeable batteries that are disposed of should be protected against short circuit and their
exposed terminals should be covered completely with insulating tape before disposal. Even empty batter-
ies/rechargeable batteries can contain residual energy that may cause them to swell, burst, catch fire or
explode in the event of a short circuit.

15 Technical data

15.1 Product
Power supply.......................................... 3 V CR123A lithium battery (1400 mAh)
Battery life............................................... Approx. 2 yrs
Standby current ...................................... <9 µA
Alarm alerts ............................................ sound + light + app notification
Alarm sound ........................................... ≥85 dB @ 3 m
Low battery warning ............................... <2.7 V
Smoke detection..................................... Photoelectric
15.2 Wireless module
Wireless frequency ................................ 2.412 to 2.484 GHz
Wireless range ....................................... 100 m
Wireless transmission power ................. 20 dBm
Standard................................................. IEEE 802.11 b/g/n
15.3 Others
Operating temperature .......................... 0 to +55 °C
Operating humidity ................................ ≤95 % RH
Storage temperature .............................. -10 to +55 °C
Storage humidity .................................... ≤95 % RH
Dimensions (W x H x D) (approx.) ......... 76 x 29 x76 mm
Weight (approx.)..................................... 83 g (product + mounting plate + battery)
DC 3 V (CR123A/2 years)
Test the alarm for correct operation using
the test facility, whenever the battery is
replaced.
Wireless protocol: Wi-Fi
Tested according to:
EN 14604:2005
EN 14604: 2005/AC:2008
6
www.conrad.com/
1008
1008-CPR-MC 69266125 0001
22
Smoke Alarm
ZR150SW
Distributed by Conrad Electronic SE,
Klaus-Conrad-Str. 1, D-92240 Hirschau
WEEE-Reg.-Nr.:
DE28001718
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2483200_V1_0522_dh_mh_en 18014398929079307-2 I3/O1 en

Werbung