Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Care; Declaration Of Conformity (Doc) - Sygonix 2483200 Bedienungsanleitung

Batteriebetriebener rauchmelder
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. Use the mounting bracket as a template for where to drill.
2. Drill 2x holes.
3. Insert the plastic dowels into the holes.
4. Attach the bracket to the wall using 2x screws.
5. Align the holes on the smoke alarm with the holes on the
6. Lock the product to the bracket by rotating it clockwise.
7. Make sure the product is securely mounted before letting
8.3 Adhesive
Preconditions:
a
The mounting surface is dry, level, non-porous and free from debris.
1. Remove the adhesive backing tape and attach it to the wall.
2. Gently press the mounting bracket against the tape and hold for approx. 30 secs.
3. Align the holes on the smoke alarm with the holes on the bracket.
4. Lock the product to the bracket by rotating it clockwise.
5. Make sure the product is securely mounted before letting go.
9 Operation
9.1 Alarm test
Important:
Due to the loudness (≥85 decibels) of the alarm, always stand an arms-length away from the
product when testing.
Test the alarm weekly to ensure correct operation.
Alarms failing an alarm test, or not operating normally, must not be used.
Short press the "test" button to test the alarm. If the alarm is working correctly, the following sound and
light signals will activate then switch off:
Continuous red flash
3x beep sounds
9.2 Normal operation
The product is functioning normally when the following sound and light signals show:
1x red flash every 40 seconds.
9.3 Smoke alarm triggered
When the smoke alarm is triggered the following warnings show:
Continuous red flash + continuous beeping sound + app alert
9.4 Low battery
Replace the battery when the following warning(s) show:
Mobile application: will show the battery status icon.
Product: 1x red flash / 1x beep every 40 seconds.
9.5 Product fault
If the product is not functioning correctly remove it from use. The following sound and light signals will
show:
2x red flash / 2x beep sound every 40 seconds.
9.6 Hush mode
Important:
This should only be used to silence an alarm (nuisance alarm) that has been triggered by a known to
be non-hazardous condition (e.g., smoke from cooking).
If a nuisance alarm has been triggered:
Press and hold the "test" button to silence the alarm for 9 minutes.
After 9 minutes, if the smoke concentration is still above the alarming point, the alarm will trigger
again.
5
bracket.
go.
10 Application "Smart Life - Smart Living"
Important:
– The product is compatible with 2.4 GHz networks.
– Enter the exact network name (case sensitive).
– Connect the mobile device to the same Wi-Fi network the product will connect to.
– If you are giving the product to a third party you did not "Share Device" with, you may need to "Re-
move Device" through the application before they can link it to their account.
10.1 Features
Low battery warning.
Push notification for smoke detected.
Check battery level and status record.
10.2 Download application
TM
Compatible Android
and iOS apps are available from their respective app stores.
Search for "Smart Life - Smart Living".
10.3 Product to application pairing
Connection pathway: Sensor → Smoke detector (Wi-Fi)
Available pairing methods are as follows:
Connection method
QR code
AP mode
EZ mode
10.4 Wi-Fi connection status
Notes:
After successfully connecting to the network, short press the "test" button and then wait approxim-
ately 10 seconds.
The app will display "caution, smoke inspected" to indicate that the product is functioning nor-
mally.
10.4.1 Product connected to Wi-Fi
The product is connected to a Wi-Fi network if the red LED flashes slowly:
After pressing and holding the test button for >5 seconds.
For a short duration after the power has been switched ON.
10.4.2 Product not connected to Wi-Fi
The product is not connected to a Wi-Fi network if the red LED flashes quickly:
After pressing and holding the test button for >5 seconds.
For a short duration after the power has been switched ON.
10.4.3 Network error
A Wi-Fi network fault is indicated by: 3x red flash / 3x chirp sounds every 40 seconds.
Check your Wi-Fi network is functioning correctly and then try to reconnect.
11 Troubleshooting
Problem
Possible cause
Alarm sounds immediately after
A lot of smoke indoors.
power on.
Internal circuit damaged.
1x beep every 40 seconds after
Low battery.
power on.
2x beep every 40 seconds after
Internal circuit damaged.
power on.
No alarm sound when performing
Battery installed incorrectly.
an alarm test.
Low battery.

12 Cleaning and care

Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions. They damage
the housing and can cause the product to malfunction.
– Do not immerse the product in water.
– Replace the battery after approx. 2 yrs
1. Carefully remove the product from the wall mount.
2. If needed, use a vacuum cleaner with soft brush tip to remove any dirt before wiping. Pay particular
attention to the smoke detection holes.
3. Clean the product with a dry, fibre-free cloth. Take care not to push any dirt into any openings on the
product, especially the smoke detection holes.
4. After cleaning, reinstall the product and perform an alarm test.

13 Declaration of Conformity (DOC)

Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau hereby declares that this product con-
forms to the 2014/53/EU directive.
Available
No
Yes
Yes
Suggested solution
Power on the device again after
smoke removed.
Remove product from use.
Contact customer service.
Replace the battery.
Remove product from use.
Contact customer service.
Reinstall the battery, observe the
correct polarity.
Replace the battery.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis