OUTDOOR UNIT INSTALLATION

Outdoor installation precaution
Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.
Determine the air outlet direction where the discharged air is not blocked.
In the case that the installation place is exposed to strong wind such as a seaside, make sure the fan
operating properly by putting the unit lengthwise along the wall or using a dust or shield plates.
Specially in windy area, install the unit in such way that the admission of wind is prevented.
Be sure there are no obstacles blocking the airflow.
ATTENTION
If need suspending installation, the installation bracket should accord with all technical
requirements. The installation wall should be strong enough or actions to reinforce should be
taken. The connection between bracket and wall, bracket and the air conditioner should be firm,
stable and reliable. In case of any doubts or uncertainty do not attempt to install the unit but
have the support calculated and engineered by a skilled engineer.
For capacities ≤ 7,0 kW: never place the outdoor unit over 5 meters higher or over 5 meters lower than the
indoor unit.
Settlement of outdoor unit
Anchor the outdoor unit with bolts, lock washers and nuts ø 10 mm or ø 8 mm tightly and horizontally on
a concrete or rigid mount.
Model
A (mm)
5.2 kW
530
5.2 kW
560

Drain joint installation

(see fig. 13)
Fit the seal into the drain elbow, then insert the drain joint into the base pan hole in the bottom of the out-
door unit, rotate 90° to assemble them securely. Connect the drain joint with an extension drain hose (not
included). In this way condensed water, which is produced during heating mode of the airconditioner, can
be drained away.
All manuals and user guides at all-guides.com
Strong
wind
Fig. 11
B (mm)
290
335
Air inlet
Air inlet
Air ourlet
Fig. 12