REMARKS FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX):

» If film of rust is possible (flying rust in the immediate product surroundings), all outer aluminium parts have to be protected
accordingly (e.g. by varnish).
» The product must be electrically connected to adequately earthed installation.
» For installation, removing or repair of the product on site, only tools allowed for the corresponding explosion area can be used.
» The product shall not be exposed to: flames, ionised radiation and ultrasound.
» Ambient temp. conditions must be considered, including possible additional heating effects due to other devices in immediate
vicinity.
EX-PROTECTION
The device does not have any potential ignition sources and thus ATEX 95 (94/9/EG) does not apply to it (applied electronic
accessories comply with the ATEX requirements).