Heat Pump Switching On And Off; Operational Parameter Setting And Checking - AZURO BP-50HS-A Installations- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.2

HEAT PUMP SWITCHING ON AND OFF

Connect the equipment to the mains (switch the circuit breaker on).
After switching the system on, press the
mode symbol.
key to switch the heat pump off . The equipment will then stay in the standby state.
Press the
In the standby state the LED panel shows the actual time (if set).
In the operating state the LED panel displays the current water temperature.
5.3

OPERATIONAL PARAMETER SETTING AND CHECKING

Pressing the buttons
Use the buttons
flash on the display) and use the
Press
to confirm the setting and return to the next level.
To exit the mode, briefly press the
and the display switches to the standard display.
No.
Target temperature in the heating mode
C0
Adjustment of thermostat sensitivity (difference between
C1
switch-out and switch-on temperatures)
C2
Automatic restart after power outage
C3
Temperature protection at compressor outlet
C7
Target temperature in the cooling mode
Adjustment of thermostat sensitivity (diff erence between
C8
switch-out and switch-on temperatures)
C12
Protection from low ambient temperature
C13
Protection from high ambient temperature
C15
Target temperature in the automatic mode
H0
Interval of checks of frosting
H1
H2
Defrosting stop temperature
Defrosting start temperature
H3
Temperature difference between evaporator inlet temperature
H4
and ambient temperature (start of defrost mode)
Ambient temperature (start of defrost mode)
H5
P0
P1
Time interval of filter pump operation after compressor operation
Note: The factory setting may diff er from the data shown in the table.
Note: It is recommended not to change any setting marked with the word NO.
key. In operation the display shows the temperature of water at the heat exchanger inlet and the heating
and
at the same time turns on the setting interface.
to scroll through the list of parameters. Press the
and
buttons to set its value.
button. If no button is pressed for approx. 20 seconds, the changes are automatically saved
Meaning
Defrosting time
Filtration pump mode
button to select the appropriate parameter (it will
Range
Setting (yes/no)
15 ~ 40 °C
1 ~ 10 °C
0(no) 1(yes)
0/1
30 ~ 120 °C
7~ 30 °C
1 ~ 10 °C
-25 ~ 20 °C
35 ~ 60 °C
7 ~ 40 °C
1 ~ 240 min.
1 ~ 25 min.
1 ~ 25 °C
-20 °C ~ 20 °C
0 °C ~ 15 °C
0 °C ~ 20 °C
0/1
30 ~ 120 min
Factory setting
yes
26 °C
yes
1 °C
yes
1
yes
100 °C
yes
23 °C
yes
1 °C
yes
-7 °C
yes
42 °C
yes
26 °C
yes
45 min
yes
8 min
12 °C
yes
yes
-3 °C
yes
5 °C
yes
20 °C
NO
0
15 min
yes
9