Herunterladen Inhalt Inhalt Diese Seite drucken

Using The Control Panel; Operation Modes; Installing The Product - nedis DEHU10WT Kurzanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
• Do not use the product when the cable or plug is damaged.
• Make sure that the electrical supply in your area matches a
voltage of 220 – 240 VAC and a frequency of 50 Hz.
• Connect to a grounded socket only.
• If necessary, use an earthed extension cable of a suitable
diameter.
• Fully extend the power cord and make sure the power cord does
not contact the product.
• When using an extension cord, use one which is as short as
possible and fully extended.
• Do not let the power cable touch hot surfaces.
• Do not close a door on the power cable.
• Do not pull the power cable to move the product.
• Do not put any objects into openings. Do not use with any
opening blocked.
• Do not use the product without the air inlet and outlet covers in
place to avoid touching hot and moving parts that may cause
injuries.
• Do not drink water from the product. This may cause illness.
• Be aware that the refrigerants should be odourless.
• The refrigerants should be added by the manufacturer, its service
agent or similar qualified persons.
• Do not use the product in temperatures below 0˚C.
• Do not expose the product to direct sunlight or rain.
• Do not spill any water on the product.
• Do not sit on the product.
• Unplug the power cable when the product is not in use for a long
time.
• Do not unplug the product by pulling on the cable. Always grasp
the plug and pull.
• Do not block the air in- and outlets of the product.
• Only install, operate and store the product in a room with a floor
area above 4 m
.
2
• Only store the product in a well-ventilated area.
• Do not use external timers or remote control systems to switch
the product on or off.
• Place the product in an area without any continuous sources of
ignition (for example: open flames, gas or electrical appliances in
operation).
• When the product is installed, operated or stored in a
non-ventilated area, make sure the room is designed to prevent
the accumulation of refrigerant leaks resulting in a risk of fire or
explosion due to ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
• When defrosting and cleaning the product, do not use any
means other than those recommended by the manufacturing
company.
• Do not puncture or heat any part of the refrigerant circuit.

Installing the product

Keep a minimum of 300 mm of free space around the product.
4
Only move the product in the upright position.
4
1. Place the product on a stable and flat surface.
2. Plug the power cable A
5
Assembling for continuous dehumidification
(optional)
1. Remove the plug from the water hose connection A
2. Place the water hose A
9
3. Connect A
9
to a water container or drainage system (not
included).
Ensure that A
is hanging down from A
4
9
cannot flow back into the product.
DEHU10WT_MAN_COMP_0522_print.indd 4
DEHU10WT_MAN_COMP_0522_print.indd 4
into a power outlet.
8
.
into A
8
.
8
, so that the water

Using the control panel

Button
Function
Press during the dehumidification or
Fan speed button B
q
ventilation mode to switch between
the high and low fan speed.
The low fan speed B
speed indicator LED B
Press to cancel or set the duration of
Timer button B
e
dehumidification.
The timer can be set to a maximum
of 24 hours.
Press B
The duration is shown in hours.
When the timer function is activated,
the time indicator LED B
Press to set the desired humidity level
- button B
r
within a range of 30% to 80%.
+ button B
t
Dehumidify mode button
Press to choose from four different
B
y
modes:
Automatic
Dehumidification
Dry laundry
Ventilation
Power on / standby
Press to switch the product on or off.
button B
u
B
q
+ B
e
Press and hold B
seconds to activate or deactivate the
child lock function.
The child lock indicator LED B
lights up.
The product might make some noise when it is used for the first
4
time or after a long period when the product was not used. This
is normal and does not affect the safety of the product.
Keep the doors and windows closed to allow the product to work
4
more efficiently.
The room temperature might increase during use, because the
4
product does not have a cooling function.

Operation modes

Automatic
Automatically switches on and off to
maintain a humidity level of 55%.
Automatically switches to high fan
speed when the room humidity level
is higher than 70%.
Automatically switches to low fan
speed when the room humidity level
is between 55% and 70%.
Automatically switches to low fan
speed when the room humidity
level is lower than 55%. The
dehumidification function is disabled.
Set humidity level and fan speed are
disabled.
The automatic dehumidification
mode indicator LED B
Dehumidification
Switch on the dehumidification and
ventilator of the product.
The humidity level and fan speed can
be set manually.
The dehumidification mode indicator
LED B
Dry laundry
To help dry clothing and upholstery
in the room.
Set humidity level and fan speed are
disabled.
The dry laundry mode indicator LED
B
8
4
2
or high fan
1
lights up.
and B
to set the time.
r
t
3
lights up.
q
and B
e
for 3
w
7
lights up.
6
lights up.
lights up.
19-5-2022 13:02:02
19-5-2022 13:02:02

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis