Plumb Up Dot Accuracy Check
GB
1.
Mount the laser tool in its horizontal position (Figure
on a tripod in a room with a ceiling that is at least 7.5m
higher than the tripod height (Figure
2.
Power ON the laser tool in Self-Levelling Mode
(Figure
).
3.
Where the Plumb Up Dot laser beam is displayed on the
ceiling, mark point A (Figure
4.
Rotate the laser tool 180° on the tripod (Figure
5.
Where the Plumb Up Dot laser beam is now displayed on
the ceiling, mark point B (Figure
6.
Measure the distance between points A and B
(Figure
).
7.
If the distance between points A and B is greater than the
allowable distance for the corresponding ceiling height in
the following table, calibration is necessary.
Allowable Distance
Ceiling Height
7.5m
15m
If calibration is required, the laser must be serviced at an
authorized service center. To locate your nearest Stanley
service center go to www.2helpU.com.
Changing the Rotation Speed
Press
to cycle through the available speeds for the rotary
laser beam.
Press
Rotary Laser Beam Speed
Default
x1
x2
0 (Plumb Dot Laser Beam)
x3
14
Adjusting the Vertical Tilt
)
The Vertical Tilt option uses the Adjustment Knob (Figure
and the level vial (Figure
).
up to +/- 5° along its length.
• To move the laser tool's base closer to the surface
(Figure
(Figure
vial will move upward (Figure
).
• To move the laser tool's base away from the surface
).
(Figure
(Figure
).
vial will move downward (Figure

Using the Detector

The Detector allows you to determine the location of the laser
bean when distance or lighting conditions make the laser beam
Between A & B
Detector Setup
4.5mm
You can hold the Detector by hand or attach it to the optional
9.0mm
clamp to mount the detector to a measuring rod, pole, or similar
object.
Using the Detector with a Clamp
1.
Guide the clamp onto the detector using the alignment holes
on the clamp (Figure
(Figure
2.
3.
Loosen the tightening knob (Figure
counterclockwise.
4.
Place the clamp onto a level staff, pole, or similar object.
Turn the tightening knob (Figure
5.
the clamp to the level staff, pole, or similar object.
300 RPM
6.
Loosen the clamp to move the detector up or down to detect
600 RPM
the Reference Level (Figure
7.
Once the Reference Level is found, turn the tightening knob
150 RPM
clockwise to hold the clamp in position.
8.
Read the position shown at the Reference Line edge of the
clamp (Figure
) to adjust the laser tool's base
), turn the Adjustment Knob clockwise
). As you turn the knob, the bubble on the level
).
), turn the Adjustment Knob counterclockwise
). As you turn the knob, the bubble on the level
).
and the back of the detector
.
).
) by turning it
) clockwise to secure
).
).
)