1. N
1.1 g
enerAl notes on sAfety
These operating instructions are valid for the MSRT-1000
roughness tester. Only qualified personnel may handle
the roughness tester.
WARNING Read all safety warnings and all in-
structions. Failure to follow the warnings and in-
structions may result in electric shock, fire and/or
serious injury.
Save all warnings and instructions for future refer-
ence.
1.2 u
se of the mAchine for purposes for
which it is intended
The roughness tester is intended for measuring the sur-
face roughness (Ra, Rz, Rq and Rt) of metallic and non-
metallic surfaces.
1.3 i
ncorrect use
All uses other than those described under section
1.2 are regarded as incorrect use and are there-
fore not admissible.
1.4 ec
declArAtion of conformity
Translations of the «EG-Koformitätserklärung (Original)».
SUHNER Schweiz AG of Industriestrasse 10, 5242 Lupfig,
hereby declares under sole responsibility that the product
with the serial or batch no. (see reverse side) complies
with the requirements under the Directive 2014/30/EU.
Applied standards: EN 61326-1:2013. Document Agent:
T. Fischer. CH-Lupfig, 07/2022.
T. Fischer/Division manager
2. C
2.1 p
rior to tAKing the mAchine into serVice
Open the case and check the
roughness tester for visible dam-
age. Damaged meters may not be
used.
Remove any protective films.
The stated supply voltage must match the provided line
voltage.
Only use SUHNER accessories that have been supplied
with the product.
The meter may not be operated in a room that contains
explosive gases. An electric spark may trigger an explo-
sion.
18
S
oTES oN
aFETy
ommISSIoNINg
2.2 t
AKing the mAchine into serVice
2.2.1 t
/t
urn on
urn off
Press the power button (2) for 2 seconds until a signal
tone is emitted. The setting of the last measurement will
be displayed. To switch the meter off, press the power
button for 2 seconds again. If the power button is not
pressed, the meter will switch itself off automatically after
a few minutes.
2.3 r

Ating dAtA

Roughness parameters
Units
µm, µ-inch (can be toggled between)
Measurement range Rz, Rt
Measurement range Ra, Rq
Measuring accuracy
Measuring repeatability
Cut-off lengths
Total sampling length
Sampling speed
Probe system
Probe tip
Diamant, 10µm ±1µm tip radius
Angle of inclination
Display
Power supply
Charger
Charging time
Weight
Size (LxBxH)
Ra (ISO), Rz (DIN), Rq, Rt
0.10 - 50µm
0.05 - 15.0µm
+15%
<12%
0.25mm/0.8mm/2.5mm
6mm
1mm/s
Piezoelectric sensor
90° (+5° or -10°)
OLED display, blue
3.7V Li-ion battery
5V DC
3 hours
0.200kg
106x70x24mm