Install as follows:
Select the location and mark up its three points for
drilling, then drill using an
marked places on the wall. (Fig. 1). As an aid, use the
prepared holes in the packaging, marked + (Fig. 2).
Select the position on the wall according to the di-
mensions stated in Figure 1. Open the box and place
it against the wall (Fig. 3). Then transfer the marked
holes to the wall.
Insert plastic plugs into the holes or other applicable
fastening devices. (Fig. 4)
Screw in the screws and let them protrude about 5
mm. (Fig. 4)
To attach the unit: move the convector to the left (1)
and downwards (2), so that the screws end up in the
top position. (Fig. 5)
Wet rooms
In wet rooms, the convector must be installed in accordance with EU directives and national regulations.*
If the convector is to be used in wet rooms, the following
installation requirements must be followed:
The convector has IP24 protection (protection against
water droplets) and can therefore be installed in "Zone 2"
(see Fig. 6). The distance between the control panel and
the water source must be at least 1 metre, in order to avoid
the risk of the control panel (thermostat) being reached
by a person who is in a shower/bathtub. If you do not feel
confident about the installation, it is recommended that an
authorised electrician is consulted.
If the above instructions cannot be implemented, it is rec-
ommended the appliance is installed in "Zone 3".
In wet rooms, the power source must be installed at a
height of at least 25 cm above the floor.
* EU electrical directives and regulations for special installations and workplaces including bathrooms, shower enclosures IEC60364-7-701.
6 mm drill bit at the
Ø
Fig. 2
Fig. 4
Zone 3
Zone 3
Zone 2
Fig. 1
Fig. 3
Fig. 5
(1)
(2)
Fig. 6
Zone 1