Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Information; Error Codes; Technical Facts - EBECO Wall Flex 500 Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Main menu: Settings
WiFi
Select network
WPS
Reset account
Time & date
Set the time
and date.
Language
Set the
desired lan-
guage.
Screen saver
Screen saver
with three dif-
ferent styles.
Keypad lock
On/Off
Summer time
On/Off
Main menu: Fitter
System info
Sensors
Calibration
Features
Adaptive
function
Ventilation
function
Reset
Reset all
Save data
Displays the selected
network and connection
status.
Wireless Protected Setup
Restores connection to
the app.
For WiFi: set the time
zone.
Swedish
English
Norwegian
Finnish
German
Preset Time & Temp.
Adjustable Time & Date
None (off)
Preset to Off
Preset to On adjusts the
clock automatically for
summer time.
Displays the
settings and
calibrations.
Room sen-
If required
sor
On/Off (preset On)
On/Off (preset On)
Saving energy
consumption. Other
settings will be reset.

Operating information

The thermostat display displays operational information.
Operating information
Right now
Display of the
current temp.
Set
After X:XX
(time in
hours until
setpoint is
Ventilation
reached)
Circle
Green
Red

Error codes

When a fault occurs, the thermostat switches off the heat-
ing. The display will then display an error code.
E1
Short circuit room sensor.
E2 Interruption room sensor

Technical facts

Connection voltage 230 VAC ±10% 50-60 Hz
Setting range
+5°C to +35°C
Power reserve
36 hrs, date and time
Colour
White RAL 9003
Enclosure class
IP24
Approval
CE, S
Room
Set point reached.
The ventilation function switches
off the heat for 15 minutes if it
detects that the temperature
drops by more than three de-
grees in less than one minute.
Heating ON
Heating OFF