Troubleshooting LED Error Codes
LED 1 and 2 are flashing: Hardware protection active • Check motor & check controller
LED 1 and 4 are flashing: Over voltage detected • Check PSU
LED 1 and 5 are flashing: Under voltage detected • Check PSU
LED 2 and 3 are flashing: Software protection active • Check motor & check controller
LED 3 and 4 are flashing: Open circuit protection active • Check all connection cables and power-cord to
ensure all are undamaged and connections are correct • If the above are ok,
check the motor
LED 4 and 5 are flashing: Impeller is jammed or broken or pump is operating dry • Check impeller
for signs of blockages/damage and ensure the Reef Pump Compact is fully
submerged