Herunterladen Inhalt Inhalt Diese Seite drucken

Admitted/Not Admitted Fuel - LA NORDICA ANTHEA Verticale Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ANTHEA – VENERE
CHIMNEY CAPS - DISTANCES AND POSITIONING
Inclination of the roof
α α α α
15°
30°
45°
60°
7.

ADMITTED/NOT ADMITTED FUEL

The fuels admitted are wood logs. One must use only logs of dry wood
wood logs should be 30 cm's long and 30 cm's max in circumference.
The wood used as fuel must have a moisture contents lower than 20 %, which is obtained after at least 1 year
drying (tender wood) or 2 years (hard wood) and must be stored in a dry and ventilated place (for ex. Under
ashed). The wet wood makes ignition more difficult because it is necessary a greater quantity of energy to
evaporate the existing water.
The humid contents has the disadvantage that, with the temperature lowering, the water condensates first in
the hearth and then in the chimney. The unseasoned wood contains about 60 % of H20, then it is not suitable
to be burnt.
Beech
Oak
Elm
Poplar
Larch*
Spruce*
Scots pine *
The following cannot be burnt: rests of coal, cut-offs, parts of barks and panels, wet wood or treated
with varnished, plastic materials. In this case the guarantee on the appliance lapses. Paper and carton
must be used only for ignition.
The combustion of wastes is forbidden by national law on the protection against emissions. This may damage
the stove and the chimney, causing health damages and claims by the neighbourhood owing to the bad smell.
The wood is not a fuel which allows a continuous operation of the appliance, as consequence the heating all
over the night is not possible.
ATTENTION: the continuous and protracted use of aromatic wood (eucalyptus, myrtle etc.) quickly damages
the cast iron parts (cleavage) of the product.
7194201 Rev.06 – EN
Distance between the roof ridge
variety
*Resinous wood not suitable for the burning
and the stack
A (m)
< 1,85 m
> 1,85 m
< 1,50 m
> 1,50 m
< 1,30 m
> 1,30 m
< 1,20 m
> 1,20 m
Kg/mc
750
900
640
470
660
450
550
UNI 10683/98
Minimum height of the stack
(measured from the outlet)
H (m)
0,50 m above the roof ridge
1,00 m from the roof
0,50 m above the roof ridge
1,30 m from the roof
0,50 m above the roof ridge
2,00 m from the roof
0,50 m above the roof ridge
2,60 m from the roof
(water content max. 20 %). The size of
KWh/Kg
moistness 20%
4,0
4,2
4,1
4,1
4,4
4,5
4,4
23

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

AntheaVenere

Inhaltsverzeichnis