Herunterladen Inhalt Inhalt Diese Seite drucken

Product Description; Transport; Technical Data - Dea STOP N Bedienungsanleitung Und Hinweise

Elektromechanische schranke
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33

2 PRODUCT DESCRIPTION

Models and contents of the package
The name STOP N identifi es a series of electromechanical barriers with different characteristics with regard to the motor power supply,
the speed of movement and the maximum length of the boom. All motorized models foresee the use of advanced control units (NET series)
equipped with anti-crush sensor, built-in 433 MHz radio receiver, speed adjustment and slow down during opening and closing.
The STOP N barriers are designed for intensive use and high traffi c areas.
The choice of the barrier must be made depending on the width of the access point and the required work cycle.
The DEA System complementary accessories are indicated in the table "PRODUCT ACCESSORIES" (pag. I-8).
The STOP N barriers have a built-in electro-mechanical operator which is connected directly to the shaft which raises and lowers the
boom, while the boom balancing by setting up the springs to the appropriate tension.
The automation control is enclosed in a steel box in painted steel (or stainless steel) with a lockable door. The control panel is installed
inside the door cover for full access.

Transport

STOP N is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information
that may be provided on the same box for storage and handling.

3 TECHNICAL DATA

Motor power supply voltage (V)
Absorbed power (W)
Type of boom used
Duty cycle (cycles/hour)
Maximum n° of operations in 24 hour
Built-in capacitor (μF)
Operating temperature range (°C)
Motor thermal protection (°C)
Opening time 90° (s)
Weight of product with package (Kg)
Protection degree
Power supply (V)
Rated power transformer (VA)
Fuse F2 (A) (transformer)
Batteries
Fuse F1 (A) (batteries input)
24V operators outputs
Warning: The above values are calculated by taking the maximum power
supplied by the respective processors. In absolute terms, the maximum
current from each output must not exceed 10A.
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
* Values for STOP with boom ≥ 6 m.
STOPNET/N/L-F
4÷6m
230 V ~ ±10% (50/60 Hz)
500
150
800
18
150
6,5
81
CONTROL BOARD
NET24N
230 V ~ ±10% (50/60 Hz)
4÷5 m
≥ 6 m
150 VA
250 VA*
(230/22V)
(230/22V)
2A
3,15A*
2x 12V 4A
15A
2x 5A
2x 7A*
24 V
(24V_AUX + 24V_ST =
max 200mA)
+24 V
max 15 W
24V
max 5W or max
1 art. 110
24 V
max 15W
-20÷50 °C
433,92 MHz
HCS fi x-code - HCS rolling
code - Dip-switch
100
OPERATOR
STOP24NET/N/V-F
>6m
4m
Refer to Table on page I-7
125
500
500
1500
-20÷50
8
2,7
IPX4
Power supply (V)
Fuse F2 (A)
Fuse F1 (A)
230V operators outputs
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
230V Flashing light output
24V Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
STOP N
STOP24NET/N/L-F
4÷6m
>6m
24 V
120
250
170
1000
800
-
-
5,3
7,5
79
NET230N
230 V ~ ±10% (50/60 Hz)
5A
160mA
2 x 600W
24 V ~
(24V_AUX + 24V_ST
= max 200mA)
24V
230 V ~ max 150W
max 1 art. 110 or 24V
output max 5W confi gurable
230 V ~ max 40W
24 V
max 100mA (for led
fl ashing light) art. AURA N
-20÷50 °C
433,92 MHz
HCS fi x-code - HCS rolling code -
Dip-switch
100
EN-3

Werbung

Inhaltsverzeichnis
loading