TESTING CONTINUITY USING TONE (SWITCH TO "TONE")
1.
Connect the test leads to the subject pair.
2.
Use a handphone at the remote end and touch the wire end(s) with the clip lead(s).
3.
Reception of tone is an indication of continuity.
TESTING CONTINUITY (SWITCH TO "CONT")
1.
Connect the test leads to the subject pair.
2.
Use "CONT" position.
3.
A bright "GREEN" light indicates continuity. The LED will not glow if the line
resistance exceeds 10KΩ.
MODULAR TESTING
1.
All above tests are available through the modular plug for line 1 only-red and green
wires.
COAX TESTING
In order to check coaxial cables, connect the red cable to the screening of the cable and
the black cable to the internal conductor. The red cable can also be connected to the
internal conductor of the cable and the black cable to the screening.
CAUTION
However, identification of live conductors is not possible. Pay attention to this in
order to prevent electric shock.
MAINTENANCE
The amplifier probe is maintenance free except for battery replacement. Remove the
screw from the battery compartment, replace the 9V battery and reassemble.
Warranty limited solely to repair or replacement;no warranty of merchantability, fitness
for a particular purpose or consequential damages.
WARRANTY
As an ISO 9001 certified enterprise we guarantee you a constant high quality of our
products. This makes us possible to grant you a guarantee of 3 years on our
PROTEC.class-products.
FIELDS OF APPLICATION
The tool is intended for use in applications as described in the operating instruction only.
Any other form of usage is not permitted and can lead to accidents or destruction of the
device. Any misuse will result in the expiry of all guarantee and warranty claims on the part
of the operator against the manufacturer.
This operating instruction is provided with large care. For the correctness and
completeness of the data, illustrations and designs no guarantee is taken over. Subject to
change.
6