Safety Information

1. Follow all instructions and guidelines.
2. Use only standard battery cells of the type AA (2 pieces).
3. Ensure that the battery cover is properly sealed to avoid debris and moisture penetration.
4. The battery should be removed in the following cases:
• Water or other liquids ingress into the appliance.
• If the display does not function.
• If the housing or the display unit is damaged.
• If the buttons do not function.
All repairs should only be carried out by an Authorised Service Agent.
3.5
Disclaimer
Information contained in this document is believed to be accurate at the time of publication, but does not constitute a
contractual offer. The right is reserved to alter specifications without prior notice. Illustrations and tabulated data are
for guidance only. Aquis does not assume liability for any damages, including subsequent damages, that may result
from incorrect installation or usage of the products. Aquis does not assume liability for damage caused by using parts
from other manufacturers.

4. Installation

4.1
First time installation of the fi lter system with the sensor unit
For initial installation of filter system with SCOUT Flowmeter, first install the filter head (see Operation
Guide "filter systems" chapter 6).
4.2
Installation of the sensor unit to an existing fi lter system
If a filter system is already in place, follow the following steps:
1. Remove connection hose from the filter head liquid outlet using an appropriate tool.
2. Connect the sensor unit with the nut directly to the filter head (use the provided flat gasket).
3. Connect the hose to the outlet of the sensor unit (use the flat gasket).
NOTE
Disconnect the fi lter head from the water supply before start of installation.
Ensure correct alignment of sensor unit with direction of fl ow (arrow on the housing).
Use only appropriate tools for the installation (spanner 19 mm).
The sensor unit should be mounted horizontally.
Don't exposes the Flowmeter to any mechanical strain; particularly take care of any leverage eff ect
from kinked or bent hoses. If necessary, brace the connections.
Use only suitable gaskets and connecting materials.
Before start of operation fl ush the system and check for leaks.
4.3
Programming and Display Unit
4.3.1 Mounting using a screw (is recommended for secure and permanent fi xation)
1. Flat head screw with max. 4 mm shaft diameter is recommended.
4.3.2 Mounting with glue dot
1. Attach the supplied glue dot to the back of the wall mounting.
2. Completely remove the protective film from the glue dot.
3. Glue the wall mounting in the desired position.
NOTE: Avoid unintentionally pulling out the connector. Handling: press the sensor cable into
the cable guide (Fig. 13).