1. General Information
The SCOUT flowmeter was specially developed for monitoring water filter cartridges. It is used to measure the
amount of filtered water and to display the remaining filter capacity until replacement.
Therefore, the filter-specific nominal-capacity must be entered into the device.
If the capacity is exhausted or if the maximum operating time of 12 month is exceeded, the filter cartridge must be
replaced.
The programming and display unit provides the following information:
nominal capacity and remaining filtration capacity of the cartridge
total filtrate volume since Flowmeter installation
filtrate volume and operation time of the last five installed filter cartridges
gal to liter

2. Technical Data

Sensor Unit
Connection
Operating pressure (min/max)
Flow rate
Pressure loss
Precision (horizontal installation)
Water temperature (min/max)
Ambient temperature (min/max)
Dimensions (BxHxT)
Installation position
Programming and Display Unit
Graphic display
Counter
Dimensions (BxHxT)
Cable incl. jack plug
Power supply

3. Instructions

3.1
General
Read the Installation and Operation Guide carefully before each installation and start of operation.
Follow all steps exactly as indicated in the instructions.
Ensure that the flow direction corresponds to the arrows on the sensor unit.
It is recommended to mount the sensor horizontally for highest accuracy.
Don't expose the Flowmeter to any mechanical stress.
Ensure that all seals and connections are made using suitable components (are included).
3.2
Measurement tips
Avoid rapidly pulsating water flow
Avoid water-air mixture
Avoid inductive interference
Be aware that the unit is calibrated to measure water flow and hence measurements may vary
with other fluids
3.3
Staff
The installation and maintenance of the SCOUT Flowmeter may only be carried out by trained and authorised
personnel.
Standard Version
inches
In 3/8" BSP F nut / out 3/8" BSP M
bar / psi
1-8 bar (14,5 – 116 psi)
l/h
15 - 500
bar
≤ 0,5
%
+/- 5
°C / °F
4-30°C (39 - 86 °F)
°C / °F
4-40°C (39 - 104 °F)
mm
80 x 39 x 42
Horizontal recommended
Standard Version
5 digits
l
Downwards 99999 to -9999
mm
80 x 54 x 29
1,5 meter; 2,5 mm
H5.5-,2.1+,10mm H-type
8