Herunterladen Inhalt Inhalt Diese Seite drucken

Circuit Diagram - AEG RTi 600 M HF Gebrauchs- Und Montageanweisung

Integrierbarer raumtemperaturregler für hochspeicher wsp 600 hf
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fix the sensor unit to the right hand side panel.
The capillary sensor should be threaded through
the heat protection plate and front the inside
through the side panel (Fig. 4). Push the capillary
sensor bulb into the bracket in the plastic
housing.
Screw the plastic housing (outer side panel), heat
protection plate and strain relief together. Use
the 2.9x9.5 screws provided for this purpose
(Fig. 4).
Fix the strain relief to the heater using the fixing
screw of the strain relief on the fan drawer
(Fig. 4).
Connect the cables of the adapter for the rocker switch to the capillary tube sensor and the
panel board terminals according to circuit diagram.
Push on the adapter for the rock switch with 3 connecting cables from interior through the
opening in the front panel to the rocker switch (wide connections on top, narrow connections on
the bottom). Push against the rocker switch to avoid that it snaps out of the plastic fascia plate.
Connect the insulated flat connector to the free plug connection of the Rti M HF controller.
Connect the cables from capillary-tube thermostat to the terminal strip according to the circuit
diagram.
Set in plastic fascia plate with illuminated rocker switch from the front into the opening on the
front panel.
Close the heater back up.
Attention: A minimum clearance of 10cm between the right-hand side panel and the wall
of the room to be heated must be kept. The air slits in the side panel must not
be covered by any objects.

2.4 Circuit Diagram

B2
Integral room thermostat
E2
Day-acting element
F2.1 Thermal release thermostat
F2.2 Safety thermostat
F3
Fan safety cut-out
M1 Fans
R2
Fan compensatory resistance
R3.1 Accelerator resistance for room thermostat
R3.2 Night set-back resistance
S
Illuminated rocker switch for day-acting
Z
element
TA
Reducing the room temperature by 3 K
Fig. 4 Heat protection plate and strain relief
We reserve the right to make any technical changes.
The AEG Conditions of Guarantee apply.
These are to be found in the instructions supplied with the heater.
For the Fitter
Additional
circuit:
Integral
thermo-
mechanical
room
thermostat
Connection cable
1/N/PE ~ 230V
13

Werbung

Inhaltsverzeichnis
loading