Manual mode
Anti-leakage
Cut in
Cut out
Max pump on
(B) MODE selection button
Selectable modes:
1) AUTO_MODE;
2) MANUAL_MODE;
3) ANTI LEAKAGE;
4) CUT_IN;
5) CUT_OUT,
6) MAX_PUMP_ON;
To unlock the choice of function press "MODE" button for 5 seconds.
Press "MODE" to scroll through the various operating modes (AUTO_MODE or MANUAL_MODE) or parameters to be
modified (CUT IN and CUT OUT) or to enable certain functions (ANTI-LEAKAGE and MAX PUMP ON). While scrolling
through the modes, the LED of the function selected will flash. On returning to AUTO_MODE the active functions will be
highlighted by the relative LED lighting up with a steady light. See paragraph 2 (Description of the functions).
Indicators on "MODE"
AUTO MODE: the pump will work in automatic mode see 9.2.1
MANUAL MODE: the pump works in manual mode see 9.2.1, and the user can decide when to switch it on or off by
acting on the "SET" button. SET-ON switched On SET-OFF switched Off.
CUT-IN: pressure setting (always enabled) minimum pressure below which the pump is activated, can be set between
1.5 and 3.0 bar, factory setting 1.8 bar; the pump is activated even if the flow is less than a minimum value of 1.5 l/min,
factory-setting.
CUT-OUT: pressure setting (disabled) pressure above which the pump stops, the factory setting for "CUT-IN" + 1 Led,
but can be increased to 6 bar.
To enable it select the function by pressing "MODE" until the LED corresponding to CUT-OUT flashes then press SET to
select the required value, exit the setting by pressing "MODE". To disable the function, press "SET" until the light
switches on to indicate OFF.
ANTI-LEAKAGE: protection against leakage. The function can be enabled or disabled: the factory setting is disabled.
When enabled, if the condition is such that the pump is started up more than 6 times in 2 minutes, it will be stopped and
the error will be indicated by means of the red LED flashing slowly on "ALARM".
To enable it select the function by pressing "MODE" until the LED flashes then press SET until the "ON" LED is switched
on. To disable it press SET until the LED switches on to indicate OFF.
Once the cause is removed, reset the alarm, if still present, see 9.2.3.
MAX PUMP ON: maximum period of operation. The function can be enabled or disabled. The factory setting is disabled.
When enabled, if the condition is such that the pump operates for more than 30 minutes, it will be stopped, no error
indication is displayed.
17
ENGLISH
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
Increase/Decrease
Increase/Decrease
OFF: disabled
ON: enabled