Reading out and setting the control parameters

Pressing the Up and Down buttons simultaneously for at least 4 s brings up a parameter
list. Some parameters can be set, others only read out. The table below summarises the
parameters:
Para-
meter
b01
b14
C02
C03
C09
P07
oPL/H
PuL/H
Str
PA
You can browse upwards through the parameter list with the Up button and downwards
with the Down button. Press the "Set" button to display the value assigned to a parameter.
You can adjust the value assigned to a settable parameter by additionally pressing the Up/
Down buttons.
3.4.3

Setting the air pressure

If too much or too little adhesive is discharged, you can change the amount by adjusting
the air pressure. More air pressure also means more adhesive and vice versa. In order to
use the level indicator, you must change parameter P07 accordingly, see Section 3.4.2.
H2200XM_DE-EN_200720.indd 23
Description
Behaviour after power-on
Lock target value,
the adjustment of the working temperature can be
locked here.
Target value lowering after time C03
Waiting time until lowering (reset with button)
Delay after heating phase has ended (heating LED bar
then lights up continuously)
Set air pressure
Operating time display (without standby „OFF")
Number of triggers displayed during operating time
Acknowledgement Service
Access to the expanded menu
Setting range
0: not locked
1: locked
- 180 K...0 K
1...999 min
1...99 min
P05...P06
Expanded menu –
Parameter levels
1/1000 hours
0 -> 1 -> 0
Password
expanded menu –
23
Starting
Factory
setting
0: Off
0
1: On
2: Auto
0
0 K
30 min
2 min
5.0 bar
0/0
1/1000
0/0
trigger
0
1
level L