1.1 Functions and features

The AC2300 – AC2305 are UPS systems designed to effortlessly handle a power
failure without the loss of important data. Because these devices are also equipped
with a backup function, you can shut down your computer or have it make a backup
without the chance of losing data. These UPS systems are all equipped with a sound
alarm which is activated as soon a power failure occurs, warning you to shut down
your computer or to make a backup.

1.2 Packing contents

The following parts need to be present in the packing:
AC2300 / AC2305 Line Interactive UPS with AVR

2.0 Remarks about Safety

In order to keep safe in using the UPS, please comply with the following:
Please charge the battery at least 24 hours before the UPS is in operation.
After the battery is discharged or over three months without operation, the battery
should be charged immediately for at least 12 hours, ensuring the battery is full
and avoiding any unnecessary damage of the battery.
The UPS is specially designed for computer only and it should not be connected
with any inductive or capacitive load, like electromotor, daylight lamp, laser
printer, etc.
The UPS is not suitable for being used in life support systems, because it may
have some problems and bring trouble to the life support systems. The
responsibility will be users', if they insist on using the UPS in life support
systems.
It is normal that the temperature of the UPS surface reaches up to 50℃ when it is
in operation.
When AC fails and the "ON" button on the front panel is pressed, the UPS will
output voltage; if the "OFF" button on the front panel is pressed, the UPS will not
output voltage.
It is forbidden to open the case, because there is danger with electricity. If there
is problem, please handle with the instruction of experts.
It is forbidden to put container containing liquid inside on the UPS, because it will
cause danger of electric shock or fire when the UPS short-circuits.
When the UPS is abnormal, please cut off power immediately and turn to experts
or the dealer for help.
As there is no overload protection of the UPS, it cannot be overloaded.
Otherwise, it would cause danger.
It is strictly forbidden to place and operate the UPS in the following
environment:
o
Place with inflammable gas or corrosive gas or much dust;
o
Place with very high temperature or very low temperature(above 42℃
or below