Anleitung_GE_GP_5537_E_SPK7__ 06.11.13 09:23 Seite 11
without obstruction.
5.3 Electrical connections
Connect the appliance to a 230 V ~ 50 Hz socket-
n
outlet with earthing contact. Minimum fuse 10
ampere.
A built-in thermostat protects the motor from
n
overloading and blocking. The pump is switched
off automatically by the thermostat if overheating
occurs and is switched on again automatically
after cooling.

6. Operation

Install the equipment on a solid and level surface.
n
Remove the ventilation screw (7).
n
Unscrew the coarse filter screw (6) and remove
n
the coarse filter (8) together with the non-return
valve (9) as shown in Figure 2. Now you can fill
the pump housing with water via the coarse filter
screw (6). Filling the intake line accelerates the
intake process.
Assemble in reverse order.
n
Open the discharge line.
n
Connect the mains cable.
n
Switch on the equipment with the power switch
n
(3) - water can be suctioned in for up to 5 minutes
(maximum suction height).
After finishing the work, switch off the equipment
n
with the power switch (3).

7. Replacing the power cable

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, however,
we recommend that you regularly check and care for
the product.
Important!
The equipment must be disconnected from the power
supply (pull the power plug) prior to performing any
maintenance.
8.1 Servicing
If the equipment becomes clogged, connect the
n
discharge line to the water line and disconnect
the suction hose. Open the water line. Switch on
the equipment several times for approx.
two seconds. This should resolve the majority of
clog-related problems.
Replacing the mains cable: Important:
n
Disconnect the equipment from the power
supply! A defective mains cable may only be
replaced by a qualified electrician.
There are no parts inside the equipment which
n
require additional maintenance.
8.2 Cleaning the coarse filter insert
Clean the coarse filter insert at regular intervals,
n
and replace it if necessary.
Remove the coarse filter screw (6) and coarse
n
filter (8) together with the non-return valve (9)
(Figure 2).
Disassemble the coarse filter insert as shown in
n
figure 3.
Do not use abrasive cleaning agents or petrol to
n
clean the coarse filter and the non-return valve.
Clean the coarse filter and the non-return valve by
n
tapping them on a flat surface. In cases of
stubborn dirt, first clean with soapy water, then
rinse with clear water and air-dry.
Assemble in reverse order.
n
8.3 Storage
If the pump is not going to be used for a long time
n
or has to be removed for the winter months, rinse
it out with water, empty it completely and allow it
to dry.
The equipment must be completely drained
n
before it is subjected to frost.
After long stoppages, make sure the rotor turns
n
correctly by briefly switching the pump on and off.
8.4 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
n
Article number of the machine
n
Identification number of the machine
n
Replacement part number of the part required
n
For our latest prices and information please go to