DECLARATION OF A STANDARDS CONFORMITY

The producer confi rms that the devices agree with CEE 90/396 standards, rule nr. 22/1997 sb. and with relevant
goverment orders. Instalation must be done with respect to valid standards. Attention, the producer refuses
any responsibility in case of direct or indirect damages which are caused due to wrong instalation, incorrect
intervention or modifi cation, insuffi cient maintenance, incorrect use and also possibly caused by other reasons
presented by items in sale conditions. This appliance is set only for skilled use and must be operated by qualifi ed
persons only. Parts set and secured by the producer or accredited person must not be rebuilt by user.

TECHNICAL DATA

Label with technical data is placed on the back side of the device. Study the electrical diagram of connection and
all following information before installation.
MODEL
NOZZLE
BURNER
NOZZLE OF BURNER
1/100 MM (2X3,0 KW)
SPT - 60 GL
NOZZLE OF BURNER
18 kW
1/100 MM (2X3,6 KW)
CONSUPTION
BURNER 2X3,0 KW
BURNER 2X3,6 KW
NOZZLE OF BURNER
1/100 MM (3x 3,0 KW)
SPT - 90 GL
NOZZLE OF BURNER
19,8 kW
1/100 MM (3x 3,6 KW)
CONSUPTION
BURNER 3x 3,0 KW
BURNER 3x 3,6 KW
NOZZLE OF BURNER
1/100 MM (3x 3,0 KW)
SPT – 90/5
NOZZLE OF BURNER
GL
1/100 MM (3x 3,6 KW)
16,8 kW
CONSUPTION
BURNER 3x 3,0 KW
BURNER 3x 3,6 KW
PACKING AND DEVICE CHECK
The device leaves our stocks properly packed with appropriate symbols and labels. There are also appropriate
instructions for use. In case the packing shows bad handling or damage, it must be reclaimed at forwarder
immediately by writing and signing of a damage protocol.
Important notice
• this instructing guide must be read properly and carefully because it contains important information about
safety elements, installation, use
• these recommendations refer to this product
• this product corresponds with valid standards
• this guide must be properly deposited for future use
• keep the children away from manipulation with the product
• when selling or moving the product to another place it is necessary to make yourself sure that the staff or the
professional service has got acquainted with control and installation instructions from enclosed guide,
12,8 kWh/kg
12,8 kWh/kg
G 30/G 31
G 31
PROPAN / BUTAN
PROPAN
28 - 30 mbar
37 mbar
85
85
96
96
0,96Kg/h
0,96Kg/h
85
85
96
96
1,44Kg/h
1,44Kg/h
85
85
96
96
1,222Kg/h
1,222Kg/h
12,8 kWh/kg
9,45 kWh/m
G 30/G 31
G 20
PROPAN / BUTAN
NATURAL GAS
50 mbar
20 mbar
75
130
80
145
0,96Kg/h
1,258m3/h
75
130
80
145
1,44Kg/h
1,887m3/h
75
130
80
145
1,222Kg/h
1,601m3/h
3
3
8,13 KWH/M3
FEEDING
G 25
TUBE
NAURAL GAS
GAS
20 MBAR
140
G 1/2"
155
G 1/2"
1,258m3/h
---
140
G 1/2"
155
G 1/2"
1,887m3/h
---
140
G 1/2"
155
G 1/2"
1,601m3/h
---
OVEN
POWER
VOLTAGE
3,1 kW
230V
3,1 kW
230V
3,1 kW
230V