V10-BP / V10-FP / V10-GP
V10-BN / V10-FN / V10-GN
( -00 / -01 / -02 / -03)
Max. frequency response V10B: 500Hz
V10F: 3kHz
V10G: 500Hz
Functional principle
pulsed
Power supply indicator
LED green (PWR)
Function indicator
LED yellow (OUT)
Alarm indicator
LED green (PWR) blinking
Alarm output
200mA, 50ms pulse length
Operating voltage
10 ... 30VDC (max.)
Output current
200mA
Current consumption
V10B: 45mA / 180mA
(Ø / peak)
V10F: 45mA / 90mA
V10G:45mA/180mA
Weight
65g
Casing material
ABS
Operating temperature
-10°C bis +55°C
Protection class
IP65
info@balluffstm.de
www.balluffstm.com
Operation
The different operation modes and parameters are set by a 4-position slide-switch
and a JOG-switch with push-button functionality.
inscription
function
+
increment
JOG-switch
push-button
(confirmation of selection)
-
decrement
- light-on/dark-on select;
slide-switch
OUT
- pulse stretching
OPT
- operation modes
TEA
- teach-modes
- signal strength display;
RUN
- selected parameters:
( + = tHi , - = tLo )
- external TEACH
V10 menu navigation
slide-switch
JOG-Switch
selection of
selection with +/-
main menu
confirm with
level 0
level 1
Dark-On/
OUT
Light-On
Output-
Mode
Off Delay
On Delay
Parameter
OPT
lock
Option
Turn
display
Display
o f f
Hysteresis
Default
TEA
fully automatic teach
Teach
1-point teach
2-point teach
Fine
tuning
Signal
RUN
0....999
strength
Operation
+ RemoteTeach
The actual setting is permanently lit up.
Flashing display means: indicated value can be selected. Confirm by pushing JOG-switch.
05/2010
8020132
Wiring
VDC
brown
teach-in
pink/grey
alarm
white
output
black
GND
PNP
blue
VDC
brown
alarm
white
output
black
teach-in
pink/grey
GND
NPN
blue
Push
JOG-switch
slide-switch
JOG-Switch
JOG-Switch
selection with +/-
selection with +/-
confirm with
confirm with
level 2
level 3
dark-on
light-on
ms
0...250
ms
0...250
n o
Y E S
n o
Y E S
Hysteresis in %
3; 6; 9; 12
4 values (default 12)
n o
factory setting
Y E S
(see teach-menu)
All automatic teach procedures:
min. value of calculated threshold = 100
max. value of calculated threshold = 850
0...127
A b S
0...999
0...999
0...999
0...999
Back to level 1
+
0...999
Actual threshold high
-
Actual threshold low
0...999
Connection
Sensor
Standard: - 0
1 + emitter
M8, 3pole
4 GND/shielding
3 + receiver
In- /Output
Standard -00:
brown
Z
PVC-cable, 5pole, 2m
white
L
blue
Z
black
L
pink
option -01:
1 (brown)
M12, 5pole
2 (white)
3 (blue)
4 (black)
5 (grey)
Z
L
option -02:
1 (brown)
Z
M8, 4pole
2 (white)
L
3 (blue)
4 (black)
option -03:
1 (brown)
M8, 4pole
2 (white)
3 (blue)
4 (black)
Mount
Put device onto DIN rail clip as shown.
Then, connect sensor cable.
teach menu and teach instruction
Manipulation
Pushing the JOG-switch activates the teach procedure. Display
execution of the teach procedure.
- Repeat teach procedure after every change in hysteresis setting.
- Hysteresis recommendation: For distances > 50% of nominal => use values 9 or 12.
Push JOG-switch to start teach
procedure. Switching threshold
is adjusted by repeated inserting
and removing of the object in the
sensing beam.
Pushing of the JOG-switch
terminates the procedure.
The object is placed statically in
the sensing beam.
Single push on the JOG-switch
executes the teach procedure.
Positioning of object 1 (resp.
distance 1) in the sensing beam
=> Push JOG-switch;
Positioning of object 2 (resp.
distance 2) in the sensing beam
=> Push JOG-switch
Manual fine tuning of all relevant
parameters:
- for optimisation after automatic
teach or
- as fully manual adjustment
without automatic teach.
(Only recommended for
processes which cannot be
adjusted by one of the automatic
procedures or for correction of
an automatic teach )
Remote teach procedure
The switching threshold of the amplifier can be
adjusted remotely through the PLC via the
teach-input (pink/grey).
Potentiometer
(N.B.: only in RUN mode!).
Threshold low
The remote teach procedure is
actuated by two pulses from the
Threshold high
PLC to the amplifier. The duration
of the first pulse selects the teach
Alarm level
mode (automatic or 2-point).
The duration of the second pulse
defines the storage of the
determined threshold value.
1.) X = 2,0 - 4,5s:
2.) X = 0,1 - 1,5s:
4
3
1
Connect amplifier to 10-30 VDC only!
Do not mount amplifier cable parallel to a
+ VDC
alarm output
If the green LED is blinking (alarm
- GND
signal output
indicator) when the amplifier is in
remote teach
operation (RUN), it indicates an unstable
4
3
+ VDC
signal. In this case, check whether the
alarm output
sensor is dirty or out of alignment.
- GND
5
signal output
remote teach
1
2
+ VDC
alarm output
- GND
4
2
signal output
3
1
Sensor and amplifier are only intended
+ VDC
remote teach
for object detection. Do not use amplifier
- GND
and sensor for personnel safety
signal output
Dismount
First unplug sensor cable connector.
Then take amplifier off the DIN rail clip as shown.
Action
The nominal switching
threshold is calculated as
mean value of the detected
high und low signal level.
ALH, tHi und tLo are
determined referring to it
dependent on selected
hysteresis.
Nominal switching threshold,
ALH, tHi, and tLo are
adjusted automatically refer-
ring to the signal level in a
(fixed) relation to each other.
The nominal switching
threshold is calculated as
mean value between Pt1 and
Pt2.
ALH, tHi und tLo are
determined referring to it
dependent on hysteresis.
POt: Adjustment of signal
amplification in 127
potentiometer steps.
AbS:The nominal switching
threshold may be moved
manually.
tLo, tHi, ALH remain
in the before auto-
matically adjusted
relation to each other.
tLo: threshold low
tHi: threshold high
ALH:alarm level
rEt: return to level 1
Required voltages
Input voltage
Input voltage
Input current:
a) Fully automatic remote teach:
(running process; preferably
1
several switching cycles)
2,0 - 4,5 s
0,1 - 30 s
0
( teach duration)
b) Remote 2-point teach:
1
0,1 - 30 s
0,1 - 1,5 s
0
teach point (condition1)
Permanent storage (100.000 times max.); The successfull teach procedure is
confirmed by a signal of 100ms duration on the alarm output.
Non permanent storage (until next power cutoff); The successful teach
procedure is confirmed by a signal of 100ms duration on the alarm output.
Attention!
power line!
Caution!
applications!
Notice
rdy
confirms successful
signal
ALH
hyst.
tHi
hyst.
nom. threshh.
hyst.
tLo
Especially recommended for cyclic
processes.
signal
2 x hyst.
ALH
hyst.
tHi
hyst.
nom. threshh.
hyst.
tLo
Pt1
ALH
hyst.
tHi
hyst.
nom. threshh.
hyst.
tLo
Pt2
Higher signal level should be teached
first.
ALH
hyst.
tHi
hyst.
AbS
hyst.
tLo
ALH
tHi
tLo
alarm
output
PNP
NPN
Signal „1": >9V
<3V
Signal „0": <5V
>6V
<3mA
<3mA
signal from PLC
X
alarm pulse
signal from PLC
X
0,1 s
alarm pulse
teach point (condition2)