S01 - RP Rotation Interval
The X8I provides a Timed rotation event that can be
automatically triggered on a routine basis using a
pre-determined interval, a pre-determined time each
day, or a pre-determined day and time each week. The
default setting for this parameter is 1 00:00. (Represents a
rotation at Monday (1) at 00:00 hours)
The values for this parameter are:
"1" for Monday to "7" for Sunday (a specific day of the
week)
"8" for every working day of the week (every day,
Monday through Friday, excluding Saturday and
Sunday)
"9'" for every day of the week (every day, Monday
through Sunday)
"t" for an interval of time (more than 1 or more
rotations per 24 hours)
"–" for disabling the Rotation Interval
If the parameter chosen above is "1" to "9", you will need
to set the time for the rotation to occur. It is in a Military
Time format.
The values for this parameter are:
"00" to "23" the Hour
"0" to "59" the Minutes
"–" the Rotation Interval is disabled.
If the parameter chosen above is "t", you will need to
set the Interval Time. This sets the required number of
rotation events per day (1 to 96).
The values for this parameter are:
A value of 1 = rotate every 24 hours
A value of 2 = rotate every 12 hours
A value of 3 = rotate every 8 hours
A value of 4 = rotate every 6 hours
A value of 6 = rotate every 4 hours
A value of 8 = rotate every 3 hours
A value of 12 = rotate every 2 hours
A value of 24= rotate every 1 hours
A value of 48 = rotate every 30 minutes
A value of 72 = rotate every 20 minutes
A value of 96 = rotate every 15 minutes
"–" the Rotation Interval is disabled.
All manuals and user guides at all-guides.com
S01 - TS Default Table Select
This parameter determines the 'Table' that will be used
by default when 'Pressure Schedule' is not active and no
table is selected remotely on a digital input. The default
setting for this parameter is T01.
The values for this parameter are:
S01 - BL Display Backlight Adjust
This parameter adjusts the backlight level for the display.
The display will temporarily increase brightness by 2
levels when a key is pressed and return to normal setting
after a period of no keypad activity. The default display
backlight level has been set to enable a 'continuous use
service life' in excess of 90000 hours while providing good
readability in all ambient light conditions. LCD display
'service life' is defined as the time period before the
backlight reduces to 50% of initial brightness. Typically
the display will remain usable for a much longer period
of time. Adjusting the backlight to high levels will reduce
service life. The default setting for this parameter is 5. The
values for this parameter are:
34
"T01" for Table T01
"T02" for Table T02
"T03" for Table T03
"T04" for Table T04
"1" to "7" 1 being the least amount of backlight and 7
being the most.